Voxel‐level linear energy transfer‐driven dose conversion factors between LEM‐ and MKM‐based treatment plans in carbon‐ion radiotherapy
Medical Physics · 2025
DOI: 10.1002/mp.70111 ↗At a glance
Journal article in Medical Physics, 2025. Written by Weiwei Wang and 4 co-authors. Institution: Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai Key Laboratory of Radiation Oncology,…. Major MEDLINE topics: Linear Energy Transfer, Heavy Ion Radiotherapy, Radiotherapy Planning, Computer-Assisted, Radiation Dosage. 21 references. Funded by: Pudong New Area Science and Technology Development Fund for Civilian Medical Research and Development Project, Natural Science Foundation of Shanghai, Natural Science Foundation of Shanghai Municipality.
Abstract (original language)
Background
Carbon‐ion radiotherapy employs distinct relative biological effectiveness (RBE) models—the local effect model (LEM) and the microdosimetric kinetic model (MKM)—which differ in their dependencies on dose‐averaged linear energy transfer ( LETd ) and absorbed dose. Conversion factors (CFs) between these models are essential for translating clinical outcomes across institutions; however, previous studies have neglected LETd‐ driven spatial heterogeneity.
Purpose
This study aimed to quantify the impact of LETd on CFs by establishing a voxel‐level framework for iso‐effective dose conversion and validating its clinical applicability.
Methods
RayStation‐optimized plans included cubic and spherical targets, as well as clinical cases of prostate and lung cancer. CFs were derived by comparing LEM‐ and MKM‐based RBE‐weighted doses. A conversion model correlating LETd with MKM/LEM parameters (, ) was developed using cubic plans (1–12 cm modulation depths) and validated against RayStation calculations. Spatial CF variations were analyzed across dose levels (≤10 Gy[RBE]) and LETd values (≤210.4 keV/µm).
Results
CFs showed primary dependence on dose and LETd . Smaller targets (2‐cm cubic) demonstrated higher LETd (83.0 keV/µm) compared with larger targets (12‐cm cubic, 38.4 keV/µm) and lower CFs (1.03 vs 1.13 at 4 Gy [RBE]). In cube plan targets (e.g., a 6‐cm cube at 7 cm depth), the model predicted voxel‐level doses with
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai Key Laboratory of Radiation Oncology, Shanghai Engineering Research Center of Proton and Heavy Ion Radiatio…
- Institute of Modern Physics, Applied Ion Beam Physics Laboratory, Fudan University, Shanghai, China.
- Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Shanghai Key Laboratory of Radiation Oncology, Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China.
Funding
- Pudong New Area Science and Technology Development Fund for Civilian Medical Research and Development Project
- Natural Science Foundation of Shanghai
- Natural Science Foundation of Shanghai Municipality
Cite
APA
Wang, W., Sun, W., Sun, J., Sheng, Y., & Zhao, J. (2025). Voxel‐level linear energy transfer‐driven dose conversion factors between LEM‐ and MKM‐based treatment plans in carbon‐ion radiotherapy. Medical Physics. https://doi.org/10.1002/mp.70111
Vancouver
Wang W, Sun W, Sun J, Sheng Y, Zhao J. Voxel‐level linear energy transfer‐driven dose conversion factors between LEM‐ and MKM‐based treatment plans in carbon‐ion radiotherapy. Medical Physics. 2025. doi:10.1002/mp.70111
BibTeX
@article{Wang2025,
author = {Wang, Weiwei and Sun, Wei and Sun, Jiayao and Sheng, Yinxiangzi and Zhao, Jingfang},
title = {Voxel‐level linear energy transfer‐driven dose conversion factors between LEM‐ and MKM‐based treatment plans in carbon‐ion radiotherapy},
journal = {Medical Physics},
year = {2025},
doi = {10.1002/mp.70111}
}
EUVIMED