EUVIMEDDescubrir EUVIMED
Crossref

Low‐cost gynecologic ultrasound phantom with tissue‐mimicking properties for hysterosalpingo contrast sonography

Tatiana Estifeeva, Galina Kalinichenko, Egor Morokov, Elena Fedotkina, Alexander Sencha, Roman Barmin iD, Polina Rudakovskaya iD

Medical Physics · 2025

DOI: 10.1002/mp.70097 ↗

At a glance

Journal article in Medical Physics, 2025. Written by Tatiana Estifeeva and 6 co-authors. Institution: Center for Photonic Science and Engineering, Skolkovo Institute of Science and Technology, Moscow, Russia. Major MEDLINE topics: Phantoms, Imaging, Contrast Media, Fallopian Tubes, Uterus. Cited 5 times so far (Crossref); 46 references. Funded by: Russian Science Foundation.

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Background

Infertility is a major global health concern, with fallopian tube blockages contributing to up to 35% of female infertility cases, and highlighting the critical need for effective tubal patency diagnostics. Hysterosalpingo‐contrast sonography (HyCoSy) is a noninvasive ultrasound technique for assessing fallopian tube patency, crucial in infertility diagnostics. Despite its advantages over x‐ray and laparoscopic methods, its clinical use is limited due to operator dependence and the need for specialized training. However, existing ultrasound phantoms lack compatibility with microbubble‐based contrast agents, restricting their effectiveness for HyCoSy training.

Purpose

This study presents a low‐cost, anatomically representative ultrasound phantom of the female reproductive system designed to support contrast agent infusion.

Methods

The phantom replicates the uterus and fallopian tubes using tissue‐mimicking materials with acoustic and mechanical properties approximating human muscle and serous membrane tissues. Fabrication was performed using 3D‐printed molds. Materials were selected and characterized based on density, Young's modulus, acoustic velocity, and attenuation slope, and compared with literature‐reported physiological ranges. Reproducibility was assessed through multiple independent fabrications, and statistical analysis was conducted to evaluate inter‐batch variability.

Results

Among 15 tested material formulations, muscle‐mimicking sample 6 exhibited a Young's modulus of 24.3 ± 4.8 kPa, an acoustic velocity of 1550 ± 5 m/s, and an attenuation slope of 0.055 ± 0.002 dB/mm/MHz—closely matching reported values for human muscle tissue (13–32 kPa, 1547 m/s, 0.05–0.054 dB/mm/MHz, respectively). Serosa‐mimicking sample 15 showed a Young's modulus of 60.7 ± 7.3 kPa, velocity of 1598 ± 5 m/s, and attenuation slope of 0.079 ± 0.002 dB/mm/MHz, closely aligning with reported ranges for serous tissue (50–500 kPa, 1575–1595 m/s, 0.048–0.157 dB/mm/MHz). Computed tomography and B‐mode ultrasound confirmed the structural integrity and formation of internal cavities in the phantom, while fluorescence and ultrasound imaging demonstrated effective retention of contrast agents during microbubble infusion. Both B‐mode and non‐linear contrast ultrasound imaging enabled clear visualization of the uterine and tubal structures.

Conclusions

The phantom demonstrates validated mechanical and acoustic properties that closely match those of human muscle and serosa, supporting its suitability for illustrating core principles of HyCoSy, including contrast agent infusion and tubal visualization. The low cost and structural reproducibility of the model make it a practical option for simulation‐based radiology training.

Subjects

MeSH terms (MEDLINE)

Phantoms, ImagingContrast MediaFallopian TubesUterusFemaleUltrasonographyHumansHysterosalpingography

Author keywords

fallopian tubesfemale reproductive systemhysterosalpingo contrast sonographytissue‐mimicking materialsultrasound imagingultrasound phantom

Substances

Contrast Media

Authors and institutions

  • Center for Photonic Science and Engineering, Skolkovo Institute of Science and Technology, Moscow, Russia.
  • Dmitry Mendeleev University of Chemical Technology of Russia, Moscow, Russia.
  • Laboratory of Acoustic Microscopy, Emanuel Institute of Biochemical Physics, Russian Academy of Sciences, Moscow, Russia.
  • Department of Visual Diagnostics, National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I. Kulakov, Ministry of Healthcare of the Russian Federation, Moscow, Russia.

ORCID profiles: Roman Barmin, Polina Rudakovskaya

Funding

  • Russian Science Foundation

Cite

APA

Estifeeva, T., Kalinichenko, G., Morokov, E., Fedotkina, E., Sencha, A., Barmin, R., & Rudakovskaya, P. (2025). Low‐cost gynecologic ultrasound phantom with tissue‐mimicking properties for hysterosalpingo contrast sonography. Medical Physics. https://doi.org/10.1002/mp.70097

Vancouver

Estifeeva T, Kalinichenko G, Morokov E, Fedotkina E, Sencha A, Barmin R, et al. Low‐cost gynecologic ultrasound phantom with tissue‐mimicking properties for hysterosalpingo contrast sonography. Medical Physics. 2025. doi:10.1002/mp.70097

BibTeX
@article{Estifeeva2025,
  author = {Estifeeva, Tatiana and Kalinichenko, Galina and Morokov, Egor and Fedotkina, Elena and Sencha, Alexander and Barmin, Roman and Rudakovskaya, Polina},
  title = {Low‐cost gynecologic ultrasound phantom with tissue‐mimicking properties for hysterosalpingo contrast sonography},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.70097}
}
Start for free →