EUVIMEDOpdag EUVIMED
Crossref

Next‐generation nonstop gated CBCT for respiratory gating lung radiotherapy: Scan time and imaging dose

Xiuxiu He, Mitchell Yu, Sean Berry, Yiming Gao, Yabo Fu, Wendy Harris, Weixing Cai, Yusuf Erdi, Kevin Stiles, Dustin Lynch, Seng Boh Lim, Laura Cervino and 4 more

Medical Physics · 2025

DOI: 10.1002/mp.70065 ↗

At a glance

Journal article in Medical Physics, 2025. Written by Xiuxiu He and 15 co-authors. Institution: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA. Major MEDLINE topics: Cone-Beam Computed Tomography, Lung Neoplasms, Radiation Dosage, Respiratory-Gated Imaging Techniques. 17 references. Funded by: NCI NIH HHS, Varian Medical Systems.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Free‐breathing gated CBCT (gCBCT) is commonly prescribed for lung cancer patients undergoing respiratory gating radiotherapy. Recently, the nonstop gated CBCT (ngCBCT) has been proposed to significantly reduce scanning time and imaging dose while preserving high image quality.

Purpose

To implement the novel ngCBCT imaging technique on a C‐arm linear accelerator (LINAC) and quantitatively compare its scan time and imaging dose with those of the current clinical gCBCT. Methods ngCBCT was implemented via a customized XML file in the developer mode of a C‐arm LINAC, while gCBCT was acquired in the clinical mode. Both techniques employed the same thorax imaging protocol (half fan, full trajectory). Scan times were calculated from the timestamps of acquired projection data. Imaging dose was characterized using the weighted Cone‐Beam Dose Index ( CBDI w ), measured with a standard CTDI body phantom and two pencil chambers placed centrally and peripherally. Respiratory motion was simulated using a CIRS motion platform with both Cos4 waveforms (3–6 s cycles) and seven clinical patient breathing traces. Gating duty cycles of 30%–60% were tested for Cos4 motion, while the same gating window was reproduced for each patient's breathing trace.

Results

Scan times for gCBCT ranged from 1.8 to 5 min, influenced by the gating duty cycle, breathing period, and waveform periodicity. In contrast, ngCBCT consistently achieved scan times of approximately 1 min. The imaging dose (CBDIw) for ngCBCT was reduced to 26.7%–60.1% of that for gCBCT, closely matching the respective gating duty cycles.

Conclusion

This study demonstrates that ngCBCT acquisition is feasible on C‐arm LINAC and offers substantial improvements in scan time and dose reduction compared to current clinical gCBCT. This novel technique has the potential to enhance patient comfort and broaden access to respiratory gating radiotherapy.

Subjects

MeSH terms (MEDLINE)

Cone-Beam Computed TomographyLung NeoplasmsRadiation DosageRespiratory-Gated Imaging TechniquesRadiotherapy, Image-GuidedLungHumansTime FactorsPhantoms, ImagingRespirationParticle Accelerators

Author keywords

imaging dosenonstop gated CBCTscan time

Authors and institutions

  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA.

Funding

  • NCI NIH HHS
  • Varian Medical Systems

Cite

APA

He, X., Yu, M., Berry, S., Gao, Y., Fu, Y., Harris, W., Cai, W., Erdi, Y., Stiles, K., Lynch, D., Lim, S. B., Cervino, L., Li, T., Li, X., Moran, J., & Zhang, H. (2025). Next‐generation nonstop gated CBCT for respiratory gating lung radiotherapy: Scan time and imaging dose. Medical Physics. https://doi.org/10.1002/mp.70065

Vancouver

He X, Yu M, Berry S, Gao Y, Fu Y, Harris W, et al. Next‐generation nonstop gated CBCT for respiratory gating lung radiotherapy: Scan time and imaging dose. Medical Physics. 2025. doi:10.1002/mp.70065

BibTeX
@article{He2025,
  author = {He, Xiuxiu and Yu, Mitchell and Berry, Sean and Gao, Yiming and Fu, Yabo and Harris, Wendy and Cai, Weixing and Erdi, Yusuf and Stiles, Kevin and Lynch, Dustin and Lim, Seng Boh and Cervino, Laura and Li, Tianfang and Li, Xiang and Moran, Jean and Zhang, Hao},
  title = {Next‐generation nonstop gated CBCT for respiratory gating lung radiotherapy: Scan time and imaging dose},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.70065}
}
Start for free →