Next‐generation nonstop gated CBCT for respiratory gating lung radiotherapy: Scan time and imaging dose
Medical Physics · 2025
DOI: 10.1002/mp.70065 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Xiuxiu He und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Lung Neoplasms, Radiation Dosage, Respiratory-Gated Imaging Techniques. Die Arbeit nennt 17 Literaturangaben. Gefördert von: NCI NIH HHS, Varian Medical Systems.
Abstract (Originalsprache)
Background
Free‐breathing gated CBCT (gCBCT) is commonly prescribed for lung cancer patients undergoing respiratory gating radiotherapy. Recently, the nonstop gated CBCT (ngCBCT) has been proposed to significantly reduce scanning time and imaging dose while preserving high image quality.
Purpose
To implement the novel ngCBCT imaging technique on a C‐arm linear accelerator (LINAC) and quantitatively compare its scan time and imaging dose with those of the current clinical gCBCT. Methods ngCBCT was implemented via a customized XML file in the developer mode of a C‐arm LINAC, while gCBCT was acquired in the clinical mode. Both techniques employed the same thorax imaging protocol (half fan, full trajectory). Scan times were calculated from the timestamps of acquired projection data. Imaging dose was characterized using the weighted Cone‐Beam Dose Index ( CBDI w ), measured with a standard CTDI body phantom and two pencil chambers placed centrally and peripherally. Respiratory motion was simulated using a CIRS motion platform with both Cos4 waveforms (3–6 s cycles) and seven clinical patient breathing traces. Gating duty cycles of 30%–60% were tested for Cos4 motion, while the same gating window was reproduced for each patient's breathing trace.
Results
Scan times for gCBCT ranged from 1.8 to 5 min, influenced by the gating duty cycle, breathing period, and waveform periodicity. In contrast, ngCBCT consistently achieved scan times of approximately 1 min. The imaging dose (CBDIw) for ngCBCT was reduced to 26.7%–60.1% of that for gCBCT, closely matching the respective gating duty cycles.
Conclusion
This study demonstrates that ngCBCT acquisition is feasible on C‐arm LINAC and offers substantial improvements in scan time and dose reduction compared to current clinical gCBCT. This novel technique has the potential to enhance patient comfort and broaden access to respiratory gating radiotherapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA.
Förderung
- NCI NIH HHS
- Varian Medical Systems
Zitieren
APA
He, X., Yu, M., Berry, S., Gao, Y., Fu, Y., Harris, W., Cai, W., Erdi, Y., Stiles, K., Lynch, D., Lim, S. B., Cervino, L., Li, T., Li, X., Moran, J., & Zhang, H. (2025). Next‐generation nonstop gated CBCT for respiratory gating lung radiotherapy: Scan time and imaging dose. Medical Physics. https://doi.org/10.1002/mp.70065
Vancouver
He X, Yu M, Berry S, Gao Y, Fu Y, Harris W, et al. Next‐generation nonstop gated CBCT for respiratory gating lung radiotherapy: Scan time and imaging dose. Medical Physics. 2025. doi:10.1002/mp.70065
BibTeX
@article{He2025,
author = {He, Xiuxiu and Yu, Mitchell and Berry, Sean and Gao, Yiming and Fu, Yabo and Harris, Wendy and Cai, Weixing and Erdi, Yusuf and Stiles, Kevin and Lynch, Dustin and Lim, Seng Boh and Cervino, Laura and Li, Tianfang and Li, Xiang and Moran, Jean and Zhang, Hao},
title = {Next‐generation nonstop gated CBCT for respiratory gating lung radiotherapy: Scan time and imaging dose},
journal = {Medical Physics},
year = {2025},
doi = {10.1002/mp.70065}
}
EUVIMED