A novel direct‐indirect dual‐layer flat‐panel detector for contrast‐enhanced breast imaging: Experimental assessment

Xiaoyu Duan, Hailiang Huang, Salman M Arnab, Yves Chevalier, Luc Laperrière, Adrian Howansky, Wei Zhao

Medical Physics · 2025

DOI: 10.1002/mp.18108 ↗

At a glance

Journal article in Medical Physics, 2025. Written by Xiaoyu Duan and 6 co-authors. Institution: Department of Radiology, Stony Brook University, New York, USA. Major MEDLINE topics: Mammography, Contrast Media, Breast, Radiographic Image Enhancement. Cited 1 times so far (Crossref); 28 references. Funded by: NIBIB NIH HHS, NIH HHS, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

In contrast‐enhanced digital mammography (CEDM) and contrast‐enhanced digital breast tomosynthesis (CEDBT), low‐energy (LE) and high‐energy (HE) images are acquired after injection of iodine contrast agent. Weighted subtraction is then applied to generate dual‐energy (DE) images, where normal breast tissues are suppressed, leaving iodinated objects enhanced. Currently, clinical systems employ a dual‐shot (DS) method, where LE and HE images are acquired with two separate exposures. However, patient motion between these exposures can cause residual breast tissue structure to appear in the recombined DE images, reducing the visibility of iodinated lesions. To address this issue, we propose a direct‐indirect dual‐layer flat‐panel detector (DI‐DLFPD), which eliminates patient motion artifact by acquiring LE and HE images simultaneously.

Purpose

This study aims to: (1) experimentally validate CEDM and CEDBT imaging using a first‐generation prototype DI‐DLFPD, (2) compare lesion conspicuity with images obtained using the DS method, (3) optimize the k‐edge filter for the DI‐DLFPD based on breast thickness.

Methods

CEDM and CEDBT images were acquired using both the prototype DI‐DLFPD and a conventional DS single‐layer detector at comparable dose levels to evaluate image quality and iodine target conspicuity. The figure of merit (FOM) was defined as the square of signal difference to noise ratio (SDNR) divided by the mean glandular dose. The selection of k‐edge filter for DI‐DLFPD was assessed based on varying breast thickness.

Results

By eliminating patient motion artifacts, DI‐DLFPD images exhibit a significant improvement (∼233%) in iodine object FOM compared to DS images affected by patient motion. Iodine quantification accuracy was also improved. The results suggest using a sliver filter for average breast thickness (4 cm) and a Tin filter for thicker breasts (8 cm) to achieve optimal iodine SDNR for DI‐DLFPD.

Conclusions

This study presents experimental results from the first‐generation prototype DI‐DLFPD for CEDM and CEDBT. A practical strategy was recommended, where the x‐ray filter for DI‐DLFPD was optimized based on the compressed breast thickness.

Subjects

MeSH terms (MEDLINE)

MammographyContrast MediaBreastRadiographic Image EnhancementHumansFemaleArtifactsPhantoms, ImagingSignal-To-Noise RatioBreast Neoplasms

Author keywords

contrast‐enhanced digital breast tomosynthesiscontrast‐enhanced mammographydual‐layer detectormotion artifact

Substances

Contrast Media

Authors and institutions

  • Department of Radiology, Stony Brook University, New York, USA.
  • Analogic Canada, Saint-Laurent, Quebec, Canada.

Funding

  • NIBIB NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Duan, X., Huang, H., Arnab, S. M., Chevalier, Y., Laperrière, L., Howansky, A., & Zhao, W. (2025). A novel direct‐indirect dual‐layer flat‐panel detector for contrast‐enhanced breast imaging: Experimental assessment. Medical Physics. https://doi.org/10.1002/mp.18108

Vancouver

Duan X, Huang H, Arnab SM, Chevalier Y, Laperrière L, Howansky A, et al. A novel direct‐indirect dual‐layer flat‐panel detector for contrast‐enhanced breast imaging: Experimental assessment. Medical Physics. 2025. doi:10.1002/mp.18108

BibTeX
@article{Duan2025,
  author = {Duan, Xiaoyu and Huang, Hailiang and Arnab, Salman M and Chevalier, Yves and Laperrière, Luc and Howansky, Adrian and Zhao, Wei},
  title = {A novel direct‐indirect dual‐layer flat‐panel detector for contrast‐enhanced breast imaging: Experimental assessment},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.18108}
}
Start for free →