EUVIMEDAtrasti EUVIMED
Korrektur

Correction to “Subsequent kilovoltage imaging‐based fiducial triangulation for intra‐fractional prostate motion monitoring and correction”

Medical Physics · 2025-08 · 52 (8)

DOI: 10.1002/mp.18009 ↗

At a glance

Korrektur in Medical Physics, published online on 2025-08-12.

SantraukaBibliografiniai duomenysCiteRelated studies

Abstract (original language)

Gevorkyan GS, Chen Q, Tegtmeier RC, et al. Subsequent kilovoltage imaging-based fiducial triangulation for intra-fractional prostate motion monitoring and correction. Med Phys. 2025;e18009. https://doi.org/10.1002/mp.17703 Due to an error in the use of units for the simulation of the 3D Gaussian model, the previously reported theoretical error catching capability of the 2D versus 3D thresholding method shown in Figure 8c,d is underestimated slightly. The updated figures for Figure 8c,d are shown below. At a tolerance of 2–2.2 σ, the simulation shows an error prevalence rate of 19%–26% flagged by the 3D method and a detection rate of 9%–13% cases with the 2D method, which translates to a sensitivity of 48%–52% for the 2D method. This agrees with the clinically observed rates of 18%–24%, 10% and 40%–55%, respectively. We also noticed a mix-up of the column order in Table 4, which is updated in Table 4 provided below. Note that in addition to the switching place of the sensitivity and precision column, the values were also updated to reflect the change in the 3D Gaussian model. It shows that the triangulation with a smaller view angle separation (15°) has higher sensitivity but at the cost of a higher false-positive rate at 52.4%, whereas a larger angle separation (90°) has perfect precision but only 44% sensitivity. These do not affect our points in the original paper that an optimal balance between these values is likely to be in the α = 30°–60° range. The errors mentioned here that need correction only occurred in our simulation study, which was provided to better explain our clinical observation. Given that these errors are small, the conclusions of this work have not changed.

Cite

APA

(2025). Correction to “Subsequent kilovoltage imaging‐based fiducial triangulation for intra‐fractional prostate motion monitoring and correction”. Medical Physics, 52(8). https://doi.org/10.1002/mp.18009

Vancouver

Correction to “Subsequent kilovoltage imaging‐based fiducial triangulation for intra‐fractional prostate motion monitoring and correction”. Medical Physics. 2025;52(8). doi:10.1002/mp.18009

BibTeX
@article{euvimed2025,
  title = {Correction to “Subsequent kilovoltage imaging‐based fiducial triangulation for intra‐fractional prostate motion monitoring and correction”},
  journal = {Medical Physics},
  year = {2025},
  volume = {52},
  number = {8},
  doi = {10.1002/mp.18009}
}
Start for free →