Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Jun Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China. Hauptthemen laut MEDLINE: Heavy Ion Radiotherapy, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Research and Development Program of Gansu, Natural Science Foundation of Gansu Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Phase‐controlled Rescanning (PCR) technique has been used in clinical practice. The feature of the phase‐controlled rescanning (PCR) method is that the beam intensity is adjusted by the accelerator actively. In this work, we developed a simplified fast rescanning method, called uniform‐spaced rescanning (USR), which does not require the active adjustment of the beam intensity by the accelerator.

Purpose

The motion compensation effectiveness of the USR was verified by comparing the four‐dimensional dose distributions (4DDDs) between the USR and PCR methods. Furthermore, 4D treatment plans based on the range‐adapted internal target volume (raITV) and four‐dimensional robust optimization (4DRO) under the beam delivery of USR were also evaluated.

Methods

4DCT datasets and respiratory curves from 25 lung tumor patients were used. The beam delivery simulations included the following scenario combinations: six prescription doses (2, 5, 10, 15, 20, 25 Gy (RBE)) under a single fraction, five beam intensities (1, 2, 3, 4, 5 × 10 8 particles per second (pps)), and three motion management techniques (no gating, gating with 30% duty cycle (DC), and gating with rescanning (2, 4, 6× USR/PCR)). Similarly, the 4DDDs of the two‐field raITV and 4DRO plans were calculated with the same beam delivery parameters. Dose metrics such as the target dose coverage of D 95 and homogeneity index (HI) were analyzed.

Results

The D 95 of the 4× USR was greater than 95% for all the beam intensity scenarios. The D 95 , HI and beam delivery time under the USR method were very similar to the PCR method with the increase of rescanning number. Under the 2, 4, 6× USR, the average CTV‐D 95 values of the raITV plans were higher than that of the 4DRO plans (94.9%/94.4%; 96.9%/96.4%; 97.7%/96.7%), and smaller HI values were observed for the raITV plans (11.7%/21.2%; 9.1%/17.7%; 7.9%/17.4%). For the organ at risks (OARs) sparing, the 4DRO plans could provide a better protection of the ipsilateral lung than the raITV plans.

Conclusion

The USR method could achieve the similar motion compensation effects to the PCR method, but the complexity of beam control is simplified. The raITV plans could provide a better target dose coverage but lower OARs sparing effects than the 4DRO plans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heavy Ion RadiotherapyRadiotherapy Planning, Computer-AssistedHumansFour-Dimensional Computed TomographyLung NeoplasmsTime FactorsRadiotherapy DosageRespiration

Stichwörter der Autor:innen

carbon ion radiotherapyfour‐dimensional planrescanning

Autor:innen und Institutionen

  • Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China.
  • Lanzhou University, Lanzhou, China.
  • Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou, China.
  • Key Laboratory of Basic Research on Heavy Ion Radiation Application in Medicine, Gansu Province, Lanzhou, China.
  • The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
  • Xijing Hospital, Fourth Military Medical University, Xian, China.

Förderung

  • National Natural Science Foundation of China
  • Key Research and Development Program of Gansu
  • Natural Science Foundation of Gansu Province
  • Youth Innovation Promotion Association, Chinese Academy of Sciences
  • Youth Innovation Promotion Association of the Chinese Academy of Sciences

Zitieren

APA

Zhang, J., An, X., Chai, N., Li, Q., & He, P. (2025). A novel uniform‐spaced fast rescanning method for carbon‐ion radiotherapy. Medical Physics. https://doi.org/10.1002/mp.17994

Vancouver

Zhang J, An X, Chai N, Li Q, He P. A novel uniform‐spaced fast rescanning method for carbon‐ion radiotherapy. Medical Physics. 2025. doi:10.1002/mp.17994

BibTeX
@article{Zhang2025,
  author = {Zhang, Jun and An, Xiaoyan and Chai, Ningning and Li, Qiang and He, Pengbo},
  title = {A novel uniform‐spaced fast rescanning method for carbon‐ion radiotherapy},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17994}
}
Kostenlos starten →