A vessel bifurcation landmark pair dataset for abdominal CT deformable image registration (DIR) validation
Medical Physics · 2025
DOI: 10.1002/mp.17907 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Medical Physics, 2025. Verfasst von Edward R Criscuolo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Duke University, Durham, North Carolina, USA. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Image Processing, Computer-Assisted, Radiography, Abdominal, Abdomen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Purpose Deformable image registration (DIR) is an enabling technology in many diagnostic and therapeutic tasks. Despite this, DIR algorithms have limited clinical use, largely due to a lack of benchmark datasets for quality assurance during development. DIRs of intra‐patient abdominal CTs are among the most challenging registration scenarios due to significant organ deformations and inconsistent image content. To support future algorithm development, here we introduce our first‐of‐its‐kind abdominal CT DIR benchmark dataset, comprising large numbers of highly accurate landmark pairs on matching blood vessel bifurcations. Acquisition and Validation Methods Abdominal CT image pairs of 30 patients were acquired from several publicly available repositories as well as the authors’ institution with IRB approval. The two CTs of each pair were originally acquired for the same patient but on different days. An image processing workflow was developed and applied to each CT image pair: (1) Abdominal organs were segmented with a deep learning model, and image intensity within organ masks was overwritten. (2) Matching image patches were manually identified between two CTs of each image pair. (3) Vessel bifurcation landmarks were labeled on one image of each image patch pair. (4) Image patches were deformably registered, and landmarks were projected onto the second image. (5) Landmark pair locations were refined manually or with an automated process. This workflow resulted in 1895 total landmark pairs, or 63 per case on average. Estimates of the landmark pair accuracy using digital phantoms were 0.7 mm ± 1.2 mm. Data Format and Usage Notes The data are published in Zenodo at https://doi.org/10.5281/zenodo.14362785 . Instructions for use can be found at https://github.com/deshanyang/Abdominal‐DIR‐QA . Potential Applications This dataset is a first‐of‐its‐kind for abdominal DIR validation. The number, accuracy, and distribution of landmark pairs will allow for robust validation of DIR algorithms with precision beyond what is currently available.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Duke University, Durham, North Carolina, USA.
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Criscuolo, E. R., Zhang, Z., Hao, Y., & Yang, D. (2025). A vessel bifurcation landmark pair dataset for abdominal CT deformable image registration (DIR) validation. Medical Physics. https://doi.org/10.1002/mp.17907
Vancouver
Criscuolo ER, Zhang Z, Hao Y, Yang D. A vessel bifurcation landmark pair dataset for abdominal CT deformable image registration (DIR) validation. Medical Physics. 2025. doi:10.1002/mp.17907
BibTeX
@article{Criscuolo2025,
author = {Criscuolo, Edward R and Zhang, Zhendong and Hao, Yao and Yang, Deshan},
title = {A vessel bifurcation landmark pair dataset for abdominal CT deformable image registration (DIR) validation},
journal = {Medical Physics},
year = {2025},
doi = {10.1002/mp.17907}
}