EUVIMEDPoznaj EUVIMED
Crossref

Singular value decomposition based under‐sampling pattern optimization for MRI reconstruction

Xinglong Liang, Luyi Han, Xinlin Zhang, Xinnian Li, Yue Sun, Tong Tong, Tao Tan, Ritse Mann

Medical Physics · 2025

DOI: 10.1002/mp.17860 ↗

At a glance

Journal article in Medical Physics, 2025. Written by Xinglong Liang and 7 co-authors. Institution: The Department of Radiology and Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands. Major MEDLINE topics: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Cited 2 times so far (Crossref); 28 references. Funded by: Macao Polytechnic University, Chinese Scholarships Council.

AbstraktSubjectsDane bibliograficzneCiteRelated studies

Abstract (original language)

Background

Magnetic resonance imaging (MRI) is a crucial medical imaging technique that can determine the structural and functional status of body tissues and organs. However, the prolonged MRI acquisition time increases the scanning cost and limits its use in less developed areas.

Purpose

The objective of this study is to design a lightweight, data‐driven under‐sampling pattern for fastMRI to achieve a balance between MRI reconstruction quality and sampling time while also being able to be integrated with deep learning to further improve reconstruction quality.

Methods

In this study, we attempted to establish a connection between k‐space and the corresponding MRI through singular value decomposition(SVD). Specifically, we apply SVD to MRI to decouple it into multiple components, which are sorted by energy contribution. Then, the sampling points that match the energy contribution in the k‐space, which correspond to each component are selected sequentially. Finally, the sampling points obtained from all components are merged to obtain a mask. This mask can be used directly as a sampler or integrated into deep learning as an initial or fixed sampling points.

Results

The experiments were conducted on two public datasets, and the results demonstrate that when the mask generated based on our method is directly used as the sampler, the MRI reconstruction quality surpasses that of state‐of‐the‐art heuristic samplers. In addition, when integrated into the deep learning models, the models converge faster and the sampler performance is significantly improved.

Conclusions

The proposed lightweight data‐driven sampling approach avoids time‐consuming parameter tuning and the establishment of complex mathematical models, achieving a balance between reconstruction quality and sampling time.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedHumansDeep LearningDimensionality Reduction

Author keywords

data‐driven reconstructionmagnetic resonance imagingunder-sampling pattern

Authors and institutions

  • The Department of Radiology and Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands.
  • The Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
  • The College of Physics and Information Engineering, Fuzhou University, Fuzhou, China.
  • Research Center of Space Control and Inertial Technology, Harbin, China.
  • Faculty of Applied Sciences, Macao Polytechnic University, Macao Special Administrative Region of China, Macao, China.

Funding

  • Macao Polytechnic University
  • Chinese Scholarships Council

Cite

APA

Liang, X., Han, L., Zhang, X., Li, X., Sun, Y., Tong, T., Tan, T., & Mann, R. (2025). Singular value decomposition based under‐sampling pattern optimization for MRI reconstruction. Medical Physics. https://doi.org/10.1002/mp.17860

Vancouver

Liang X, Han L, Zhang X, Li X, Sun Y, Tong T, et al. Singular value decomposition based under‐sampling pattern optimization for MRI reconstruction. Medical Physics. 2025. doi:10.1002/mp.17860

BibTeX
@article{Liang2025,
  author = {Liang, Xinglong and Han, Luyi and Zhang, Xinlin and Li, Xinnian and Sun, Yue and Tong, Tong and Tan, Tao and Mann, Ritse},
  title = {Singular value decomposition based under‐sampling pattern optimization for MRI reconstruction},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17860}
}
Start for free →