At a glance

Journal article in Medical Physics, 2025. Written by Jooho Lee and 4 co-authors. Institution: Department of Artificial Intelligence, Yonsei University, Seoul, Republic of Korea. Major MEDLINE topics: Artifacts, Metals, Tomography, X-Ray Computed, Neural Networks, Computer. Cited 4 times so far (Crossref); 68 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Research Foundation of Korea, Ministry of Science and ICT, South Korea.

SantraukaSubjectsBibliografiniai duomenysCiteRelated studies

Abstract (original language)

Background

The presence of metal objects in computed tomography (CT) imaging introduces severe artifacts that degrade image quality and hinder accurate diagnosis. While several deep learning‐based metal artifact reduction (MAR) methods have been proposed, they often exhibit poor performance on unseen data and require large datasets to train neural networks.

Purpose

In this work, we propose a sinogram inpainting method for metal artifact reduction that leverages a neural attenuation field (NAF) as a prior. This new method, dubbed NAFMAR, operates in a self‐supervised manner by optimizing a model‐based neural field, thus eliminating the need for large training datasets.

Methods

NAF is optimized to generate prior images, which are then used to inpaint metal traces in the original sinogram. To address the corruption of x‐ray projections caused by metal objects, a 3D forward projection of the original corrupted image is performed to identify metal traces. Consequently, NAF is optimized using a metal trace‐masked ray sampling strategy that selectively utilizes uncorrupted rays to supervise the network. Moreover, a metal‐aware loss function is proposed to prioritize metal‐associated regions during optimization, thereby enhancing the network to learn more informed representations of anatomical features. After optimization, the NAF images are rendered to generate NAF prior images, which serve as priors to correct original projections through interpolation. Experiments are conducted to compare NAFMAR with other prior‐based inpainting MAR methods.

Results

The proposed method provides an accurate prior without requiring extensive datasets. Images corrected using NAFMAR showed sharp features and preserved anatomical structures. Our comprehensive evaluation, involving simulated dental CT and clinical pelvic CT images, demonstrated the effectiveness of NAF prior compared to other prior information, including the linear interpolation and data‐driven convolutional neural networks (CNNs). NAFMAR outperformed all compared baselines in terms of structural similarity index measure (SSIM) values, and its peak signal‐to‐noise ratio (PSNR) value was comparable to that of the dual‐domain CNN method.

Conclusions

NAFMAR presents an effective, high‐fidelity solution for metal artifact reduction in 3D tomographic imaging without the need for large datasets.

Subjects

MeSH terms (MEDLINE)

ArtifactsMetalsTomography, X-Ray ComputedNeural Networks, ComputerImage Processing, Computer-AssistedHumans

Author keywords

3D deep learningmetal artifact reductionneural fieldsinogram inpaintingx‐ray CT

Substances

Metals

Authors and institutions

  • Department of Artificial Intelligence, Yonsei University, Seoul, Republic of Korea.
  • School of Integrated Technology, Yonsei University, Seoul, Republic of Korea.
  • Department of Radiology, Stanford University, California, USA.

Funding

  • National Research Foundation of Korea
  • Ministry of Science and ICT, South Korea

Cite

APA

Lee, J., Kim, S., Ahn, J., Wang, A. S., & Baek, J. (2025). X‐ray CT metal artifact reduction using neural attenuation field prior. Medical Physics. https://doi.org/10.1002/mp.17859

Vancouver

Lee J, Kim S, Ahn J, Wang AS, Baek J. X‐ray CT metal artifact reduction using neural attenuation field prior. Medical Physics. 2025. doi:10.1002/mp.17859

BibTeX
@article{Lee2025,
  author = {Lee, Jooho and Kim, Seongjun and Ahn, Junhyun and Wang, Adam S and Baek, Jongduk},
  title = {X‐ray CT metal artifact reduction using neural attenuation field prior},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17859}
}
Start for free →