EUVIMEDEUVIMED entdecken
Multizentrische StudieValidierungsstudie

Postal dosimetry audit for scanning proton beam using radiophotoluminescence glass dosimeter: A multicenter pilot study

Keisuke Yasui, Miuna Hayashi, Shiryu Otsuka, Toshiyuki Toshito, Chihiro Omachi, Masaya Ichihara, Riki Oshika, Yuki Tominaga, Hiromi Baba, Hidetoshi Shimizu, Naoki Hayashi

Medical Physics · 2025

DOI: 10.1002/mp.17790 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Medical Physics, 2025. Verfasst von Keisuke Yasui und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Physics, School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan. Hauptthemen laut MEDLINE: Glass, Proton Therapy, Radiation Dosimeters, Radiometry. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate dosimetry is important in radiotherapy, and all equipment used for radiotherapy shoud be audited by an independent external dose audit. Radiophotoluminescence glass dosimeter (RPLD) has excellent characteristics and is widely used for postal dose audit; however, postal dose audit for proton therapy using RPLD has not been established.

Purpose

This study aims to develop a postal dose audit procedure for scanning proton beams using RPLD, estimate uncertainties, and conduct a multicenter pilot study to validate the methodology.

Methods

A postal toolkit was developed and a postal dose audit procedure for RPLD measurements of scanning proton beams was established in cooperation with several facilities that employ various accelerators, irradiation equipment, and treatment planning systems (TPS) for clinical use. Based on basic and previous studies, an uncertainty budget was developed for estimating relative uncertainty and pilot studies were conducted at each site. A method for postal dose audits was developed in a multicenter collaboration to develop an approach suitable for implementation across multiple facilities.

Results

The relative response of 60 RPLDs for scanning proton beam examined in this study was 1.00 ± 1.28% mean ± standard deviation. The combined relative standard uncertainty of postal dosimetry for scanning proton beams using the RPLD was 2.97% (k = 1). Under the reference condition, the maximum differences between the ionization chamber measurement (IC) and TPS, RPLD and TPS, and RPLD and IC were 0.97, 1.88, and 2.12%, respectively. The maximum differences between the RPLD and ionization chamber for plateau measurements at 3 cm depth using single‐energy and non‐reference conditions were 11.31 and 4.02%, respectively.

Conclusion

We established a procedure for the postal dose audits of proton beams using RPLD and presented the results of a multicenter pilot study. By standardizing the reference conditions, the dosimetry uncertainty was estimated at 2.92%. The results demonstrated the feasibility of performing an independent third‐party dose audit of scanning proton beams using RPLD, and for such postal dose audits for proton beams, the irradiation conditions should be standardized to reduce uncertainties. These results are expected to contribute to the development of proton beams.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlassProton TherapyRadiation DosimetersRadiometryPilot ProjectsRadiotherapy DosageUncertainty

Stichwörter der Autor:innen

dose auditproton therapyradiophotoluminescence glass dosimeter

Autor:innen und Institutionen

  • Division of Medical Physics, School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
  • Department of Radiology, Aichi Medical University Hospital, Nagakute, Aichi, Japan.
  • Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan.
  • Nagoya Proton Therapy Center, Nagoya City University West Medical Center, Nagoya, Aichi, Japan.
  • Narita Memorial Proton Center, Toyohashi, Aichi, Japan.
  • Section of Radiation Safety and Quality Assurance, National Cancer Center Hospital East, Kashiwa-shi, Chiba, Japan.

Förderung

  • JSPS KAKENHI

Zitieren

APA

Yasui, K., Hayashi, M., Otsuka, S., Toshito, T., Omachi, C., Ichihara, M., Oshika, R., Tominaga, Y., Baba, H., Shimizu, H., & Hayashi, N. (2025). Postal dosimetry audit for scanning proton beam using radiophotoluminescence glass dosimeter: A multicenter pilot study. Medical Physics. https://doi.org/10.1002/mp.17790

Vancouver

Yasui K, Hayashi M, Otsuka S, Toshito T, Omachi C, Ichihara M, et al. Postal dosimetry audit for scanning proton beam using radiophotoluminescence glass dosimeter: A multicenter pilot study. Medical Physics. 2025. doi:10.1002/mp.17790

BibTeX
@article{Yasui2025,
  author = {Yasui, Keisuke and Hayashi, Miuna and Otsuka, Shiryu and Toshito, Toshiyuki and Omachi, Chihiro and Ichihara, Masaya and Oshika, Riki and Tominaga, Yuki and Baba, Hiromi and Shimizu, Hidetoshi and Hayashi, Naoki},
  title = {Postal dosimetry audit for scanning proton beam using radiophotoluminescence glass dosimeter: A multicenter pilot study},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17790}
}
Kostenlos starten →