Fachartikel in der Zeitschrift Current Oncology, 2024. Verfasst von Suresh Rana und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Boca Raton, FL 33486, USA. Hauptthemen laut MEDLINE: Head and Neck Neoplasms, Proton Therapy, Radiotherapy, Intensity-Modulated, Radiotherapy Dosage. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In current clinical practice, intensity-modulated proton therapy (IMPT) head and neck cancer (HNC) plans are generated using a constant relative biological effectiveness (cRBE) of 1.1. The primary goal of this study was to explore the dosimetric impact of proton range uncertainties on RBE-weighted dose (RWD) distributions using a variable RBE (vRBE) model in the context of bilateral HNC IMPT plans.

Methods

The current study included the computed tomography (CT) datasets of ten bilateral HNC patients who had undergone photon therapy. Each patient’s plan was generated using three IMPT beams to deliver doses to the CTV_High and CTV_Low for doses of 70 Gy(RBE) and 54 Gy(RBE), respectively, in 35 fractions through a simultaneous integrated boost (SIB) technique. Each nominal plan calculated with a cRBE of 1.1 was subjected to the range uncertainties of ±3%. The McNamara vRBE model was used for RWD calculations. For each patient, the differences in dosimetric metrices between the RWD and nominal dose distributions were compared.

Results

The constrictor muscles, oral cavity, parotids, larynx, thyroid, and esophagus showed average differences in mean dose (Dmean) values up to 6.91 Gy(RBE), indicating the impact of proton range uncertainties on RWD distributions. Similarly, the brachial plexus, brain, brainstem, spinal cord, and mandible showed varying degrees of the average differences in maximum dose (Dmax) values (2.78–10.75 Gy(RBE)). The Dmean and Dmax to the CTV from RWD distributions were within ±2% of the dosimetric results in nominal plans.

Conclusion

The consistent trend of higher mean and maximum doses to the OARs with the McNamara vRBE model compared to cRBE model highlighted the need for consideration of proton range uncertainties while evaluating OAR doses in bilateral HNC IMPT plans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Head and Neck NeoplasmsProton TherapyRadiotherapy, Intensity-ModulatedRadiotherapy DosageRadiotherapy Planning, Computer-AssistedHumansUncertaintyRelative Biological EffectivenessRadiometry

Stichwörter der Autor:innen

IMPTRBE-weighted dosehead and neck cancerproton therapyvariable RBE

Autor:innen und Institutionen

  • Department of Radiation Oncology, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Boca Raton, FL 33486, USA.
  • Department of Radiation Oncology, Florida International University, Miami, FL 33199, USA.
  • Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW 2522, Australia.

ORCID-Profile: Suresh Rana, Noufal Manthala Padannayil, Linh Tran, Anatoly B Rosenfeld

Zitieren

APA

Rana, S., Manthala Padannayil, N., Tran, L., Rosenfeld, A. B., Saeed, H., & Kasper, M. (2024). Quantifying the Dosimetric Impact of Proton Range Uncertainties on RBE-Weighted Dose Distributions in Intensity-Modulated Proton Therapy for Bilateral Head and Neck Cancer. Current Oncology. https://doi.org/10.3390/curroncol31070272

Vancouver

Rana S, Manthala Padannayil N, Tran L, Rosenfeld AB, Saeed H, Kasper M. Quantifying the Dosimetric Impact of Proton Range Uncertainties on RBE-Weighted Dose Distributions in Intensity-Modulated Proton Therapy for Bilateral Head and Neck Cancer. Current Oncology. 2024. doi:10.3390/curroncol31070272

BibTeX
@article{Rana2024,
  author = {Rana, Suresh and Manthala Padannayil, Noufal and Tran, Linh and Rosenfeld, Anatoly B and Saeed, Hina and Kasper, Michael},
  title = {Quantifying the Dosimetric Impact of Proton Range Uncertainties on RBE-Weighted Dose Distributions in Intensity-Modulated Proton Therapy for Bilateral Head and Neck Cancer},
  journal = {Current Oncology},
  year = {2024},
  doi = {10.3390/curroncol31070272}
}
Kostenlos starten →