Impact of range uncertainties for intensity‐modulated mixed electron‐photon radiation therapy

Veng Jean Heng, Marc-André Renaud, Monica Serban, Jan Seuntjens

Medical Physics · 2025

DOI: 10.1002/mp.17771 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Veng Jean Heng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, McGill University, Montreal, Canada. Hauptthemen laut MEDLINE: Photons, Electrons, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Fonds de recherche du Québec - Nature et technologies, CIHR, Fonds de recherche du Québec – Nature et technologies.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In the context of mixed electron‐photon radiation therapy (MBRT), while the necessity of robust optimization to setup uncertainties is well‐established, range uncertainties have yet to be investigated.

Purpose

This study provides the first assessment of the impact of range uncertainties on MBRT plans.

Methods

The percent depth dose of 2 electron beams (6 MeV and 20 MeV) and 1 photon beam (6 MV) are calculated by Monte Carlo using EGSnrc in slab phantoms. Range uncertainties are simulated by generating two copies of the phantom with each voxel's mass density upscaled or downscaled by 3.5%. Two clinical plans for a leg sarcoma case and a post‐mastectomy breast case were replanned with MBRT with 2 optimization methods: once without robust optimization and once with robust to both setup and range uncertainties.

Results

Dose discrepancies between the percent depth doses of density‐scaled phantoms and the nominal phantom were found to be much larger for electron beams than photons with maximum differences of 6.9% (6 MeV) and 5.5% (20 MeV) versus 1.6% (6 MV) of the maximum dose. In both clinical cases, the region of largest dose discrepancy between the range and nominal scenarios was found to be along the electron's beam path, starting immediately downstream from the target and within a few cm. Even without robust optimization, dose‐volume histograms (DVHs) of all relevant structures were not meaningfully degraded under range scenarios. In the breast plan, the ipsilateral lung's V20Gy increased by 1.9% under the worst range scenario. No substantial change in the DVHs of range scenarios were observed between the robustly and non‐robustly optimized plan.

Conclusion

In the two investigated cases, robustness to range uncertainties was not improved in robustly optimized versus non‐robustly optimized plans. A larger study comprising more patients and treatment sites remains to be performed to adequately assess the necessity of robust optimization of MBRT plans to range uncertainties.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotonsElectronsRadiotherapy, Intensity-ModulatedUncertaintyRadiotherapy Planning, Computer-AssistedHumansPhantoms, ImagingMonte Carlo MethodRadiotherapy DosageBreast Neoplasms

Stichwörter der Autor:innen

mixed beam radiation therapyrange uncertaintyrobust optimization

Autor:innen und Institutionen

  • Department of Physics, McGill University, Montreal, Canada.
  • Medical Physics Unit, McGill University, Montreal, Canada.
  • Gray Oncology Solutions, Montreal, Canada.
  • Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Canada.
  • Department of Radiation Oncology, University of Toronto, Toronto, Canada.
  • Department of Medical Biophysics, University of Toronto, Toronto, Canada.

Förderung

  • Fonds de recherche du Québec - Nature et technologies
  • CIHR
  • Fonds de recherche du Québec – Nature et technologies
  • Canadian Institutes of Health Research

Zitieren

APA

Heng, V. J., Renaud, M. A., Serban, M., & Seuntjens, J. (2025). Impact of range uncertainties for intensity‐modulated mixed electron‐photon radiation therapy. Medical Physics. https://doi.org/10.1002/mp.17771

Vancouver

Heng VJ, Renaud MA, Serban M, Seuntjens J. Impact of range uncertainties for intensity‐modulated mixed electron‐photon radiation therapy. Medical Physics. 2025. doi:10.1002/mp.17771

BibTeX
@article{Heng2025,
  author = {Heng, Veng Jean and Renaud, Marc-André and Serban, Monica and Seuntjens, Jan},
  title = {Impact of range uncertainties for intensity‐modulated mixed electron‐photon radiation therapy},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17771}
}
Kostenlos starten →