EUVIMEDObjevte EUVIMED
VergleichsstudieOpen access

Comparative analysis of auger electron emission libraries and Monte Carlo track structure codes for DNA‐targeted auger electron therapy

Alexandre França Velo, Lukas Carter, Michael Bellamy, Brian M Zeglis, John L Humm

Medical Physics · 2025

DOI: 10.1002/mp.17766 ↗

At a glance

Vergleichsstudie in Medical Physics, 2025. Written by Alexandre França Velo and 4 co-authors. Institution: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA. Major MEDLINE topics: Monte Carlo Method, Electrons, DNA. Cited 3 times so far (Crossref); 54 references. The full text is freely available in PubMed Central. Funded by: NCI NIH HHS, NIH HHS, National Institutes of Health.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Over the past decade, theranostic radiopharmaceuticals have gained significant attention, driven by the clinical success of agents like [ 177 Lu]Lu‐DOTATATE and [ 177 Lu]Lu‐PSMA‐617. This has spurred an interest in radionuclides that could produce an even more focal radiotoxicity. Radionuclides that decay by electron capture and /or internal conversion result in a cascade of low‐energy Auger electrons that produce a dense cluster of ionizations local to the decay site. These radionuclides are especially potent when the decay occurs near or at the DNA. Among these, 123 I stands out for its clinical potential as a theranostic isotope.

Purpose

This study aims to evaluate and compare two well‐recognized data libraries to obtain the Auger electron energy spectra and three Monte Carlo (MC) track codes to analyze DNA‐scale energy deposition from Auger electrons emitted by 123 I. By examining variability in simulation outputs, this study seeks to determine whether the data libraries yield different DNA double strand break (dsb) outcomes and to assess the sensitivity of the MC track codes.

Methods

An in‐house MC code was developed in MATLAB to obtain Auger electron energy spectra using the McGuire and Evaluated Atomic Data Library (EADL) datasets. A MC study using Geant4 utilized these spectra to analyze DNA dsb yields, applying a 17.5 eV threshold to define strand breaks. Subsequently, a sensitivity analysis compared energy deposition and dsb yields across MC track codes — Geant4, PHITS, and MCNP6.2 — assessing their effectiveness in modeling DNA damage from Auger emitters and bench‐marking these findings against literature data using Moca7B.

Results

The study found that the average dsb yields for the 123 I atom were similar using both McGuire and EADL libraries. Emission spectra indicated that while the McGuire library produced an average of 11.91 electrons per decay, the EADL library resulted in 13.96 electrons per decay. For different track codes, dsb yields were 0.91 for MCNP6.2, 0.60 for Geant4, and 0.43 for PHITS, whereas the dsb yield in the literature is 0.73. These discrepancies clearly emphasize the need for specific energy thresholds to align with the track code in use.

Conclusions

The EADL library produces more electrons than McGuire, but this does not affect the amount of local DNA damage significantly, as most of the additional electrons fall below the 17.5 eV damage threshold. Both libraries yield similar DNA damage outcomes. In addition, our analysis highlights the need for specific energy thresholds in MC codes to ensure accurate DNA damage predictions in Auger electron studies.

Subjects

MeSH terms (MEDLINE)

Monte Carlo MethodElectronsDNADNA Breaks, Double-Stranded

Author keywords

Auger electron therapyAuger stochastic spectrumDNA damageMonte Carlo simulationtheranostic

Substances

DNA

Authors and institutions

  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA.
  • Department of Chemistry, Hunter College, New York, USA.

Funding

  • NCI NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

França Velo, A., Carter, L., Bellamy, M., Zeglis, B. M., & Humm, J. L. (2025). Comparative analysis of auger electron emission libraries and Monte Carlo track structure codes for DNA‐targeted auger electron therapy. Medical Physics. https://doi.org/10.1002/mp.17766

Vancouver

França Velo A, Carter L, Bellamy M, Zeglis BM, Humm JL. Comparative analysis of auger electron emission libraries and Monte Carlo track structure codes for DNA‐targeted auger electron therapy. Medical Physics. 2025. doi:10.1002/mp.17766

BibTeX
@article{FranaVelo2025,
  author = {França Velo, Alexandre and Carter, Lukas and Bellamy, Michael and Zeglis, Brian M and Humm, John L},
  title = {Comparative analysis of auger electron emission libraries and Monte Carlo track structure codes for DNA‐targeted auger electron therapy},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17766}
}
Start for free →