EUVIMEDEUVIMED entdecken
Crossref

Assessment of dual time point protocols to produce parametric K i images in FDG PET/CT: A virtual clinical study

Niloufar Reshtebar, Seyed Abolfazl Hosseini, Mingzan Zhuang, Arman Rahmim, Nicolas A Karakatsanis, Peyman Sheikhzadeh

Medical Physics · 2024

DOI: 10.1002/mp.17391 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Niloufar Reshtebar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Energy Engineering, Sharif University of Technology, Tehran, Iran. Hauptthemen laut MEDLINE: Fluorodeoxyglucose F18, Positron Emission Tomography Computed Tomography, Image Processing, Computer-Assisted. Die Arbeit nennt 57 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This simulation study investigated the feasibility of generating Patlak K i images using a dual time point (DTP‐ K i ) scan protocol involving two 3‐min/bed routine static PET scans and, subsequently, assessed DTP‐ K i performance for an optimal DTP scan time frame combination, against conventional Patlak K i estimated from complete 0–93 min dynamic PET data.

Methods

Six realistic heterogeneous tumors of different characteristic spatiotemporal [ 18 F]FDG uptake distributions for three noise levels commonly found in clinical studies and 20 noise realizations ( N = 360 samples) were produced by analytic simulations of the XCAT phantom. Subsequently, DTP‐ K i images were generated by performing standard linear indirect Patlak analysis with t*‐min (Patlak t* = 12 ) using a scaled population‐based input function (sPBIF) model on 66 combinations of early and late 3‐min/bed static whole‐body PET reconstructed images. All DTP‐ K i images were evaluated against respective DTP‐ K i images estimated with Patlak t* = 12 and 0–93 min individual input functions (iIFs) and against gold standard K i images estimated with Patlak t* = 12 , 0–93 min iIFs and tissue time activity curves from all reconstructed WB passes 12–93 min post injection. The optimal combination of early and late frames, in terms of attaining the highest correlation between DTP‐ K i with sPBIF and gold standard K i was also determined from a set of 66 different combinations of 2‐min early and late frames. Moreover, the performance of DTP‐ K i with sPBIF was compared against that of the retention index (RI) in terms of their correlation to the gold standard K i . Finally, the feasibility and practicality of DTP protocol in the clinic were assessed through the analysis of nine patients.

Results

High correlations (>0.9) were observed between DTP‐ K i values from sPBIF and those from iIFs for all evaluated DTP protocols while the mean AUC difference between sPBIF and iIFs was less than 10%. The percentage difference of mean values between DTP‐ K i from sPBIF and from iIFs was less than 1%. DTP K i from sPBIF exhibited significantly higher correlation with gold standard K i , in contrast to RI, across all 66 DTP protocols ( p < 0.05 using the two‐tailed t ‐test by Williams) with the highest correlation attained for the 50‐53‐min early + 90‐93‐min late scan time frames (optimal DTP protocol).

Conclusion

Feasibility of generating Patlak K i [ 18 F] FDG images from an early and a late post injection 3‐min/bed routine static scan using a population‐based input function model was demonstrated and an optimal DTP scan protocol was determined. The results indicated high correlations between DTP‐ K i and gold‐standard K i images that are significantly larger than those between RI and gold‐standard K i .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorodeoxyglucose F18Positron Emission Tomography Computed TomographyImage Processing, Computer-AssistedHumansTime FactorsPhantoms, ImagingFeasibility Studies

Stichwörter der Autor:innen

compartmental modelingdual time pointparametric imaging

Substanzen

Fluorodeoxyglucose F18

Autor:innen und Institutionen

  • Department of Energy Engineering, Sharif University of Technology, Tehran, Iran.
  • Department of Nuclear Medicine, Meizhou People's Hospital, Meizhou, China.
  • Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, British Columbia, Canada.
  • Departments of Radiology and Physics, University of British Columbia, Vancouver, British Columbia, Canada.
  • Department of Radiology, Weill Cornell Medical College of Cornell University, New York, New York, USA.
  • Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.

Zitieren

APA

Reshtebar, N., Hosseini, S. A., Zhuang, M., Rahmim, A., Karakatsanis, N. A., & Sheikhzadeh, P. (2024). Assessment of dual time point protocols to produce parametric K i images in FDG PET/CT: A virtual clinical study. Medical Physics. https://doi.org/10.1002/mp.17391

Vancouver

Reshtebar N, Hosseini SA, Zhuang M, Rahmim A, Karakatsanis NA, Sheikhzadeh P. Assessment of dual time point protocols to produce parametric K i images in FDG PET/CT: A virtual clinical study. Medical Physics. 2024. doi:10.1002/mp.17391

BibTeX
@article{Reshtebar2024,
  author = {Reshtebar, Niloufar and Hosseini, Seyed Abolfazl and Zhuang, Mingzan and Rahmim, Arman and Karakatsanis, Nicolas A and Sheikhzadeh, Peyman},
  title = {Assessment of dual time point protocols to produce parametric K i images in FDG PET/CT: A virtual clinical study},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.17391}
}
Kostenlos starten →