Characterizing devices for validation of dose, dose rate, and LET in ultra high dose rate proton irradiations

Nathan Harrison, Serdar Charyyev, Cristina Oancea, Alexander Stanforth, Edgar Gelover, Shuang Zhou, William S Dynan, Tiezhi Zhang, Steven Biegalski, Liyong Lin

Medical Physics · 2024

DOI: 10.1002/mp.17359 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Medical Physics, 2024. Verfasst von Nathan Harrison und 9 weiteren Autor:innen. Beteiligte Einrichtung: Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Proton Therapy, Linear Energy Transfer, Radiotherapy Dosage. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 66 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ultra high dose rate (UHDR) radiotherapy using ridge filter is a new treatment modality known as conformal FLASH that, when optimized for dose, dose rate (DR), and linear energy transfer (LET), has the potential to reduce damage to healthy tissue without sacrificing tumor killing efficacy via the FLASH effect.

Purpose

Clinical implementation of conformal FLASH proton therapy has been limited by quality assurance (QA) challenges, which include direct measurement of UHDR and LET. Voxel DR distributions and LET spectra at planning target margins are paramount to the DR/LET‐related sparing of organs at risk. We hereby present a methodology to achieve experimental validation of these parameters.

Methods

Dose, DR, and LET were measured for a conformal FLASH treatment plan involving a 250‐MeV proton beam and a 3D‐printed ridge filter designed to uniformly irradiate a spherical target. We measured dose and DR simultaneously using a 4D multi‐layer strip ionization chamber (MLSIC) under UHDR conditions. Additionally, we developed an “ u nder‐ s ample and re cover (USRe)” technique for a high‐resolution pixelated semiconductor detector, Timepix3, to avoid event pile‐up and to correct measured LET at high‐proton‐flux locations without undesirable beam modifications. Confirmation of these measurements was done using a MatriXX PT detector and by Monte Carlo (MC) simulations.

Results

MC conformal FLASH computed doses had gamma passing rates of >95% (3 mm/3% criteria) when compared to MatriXX PT and MLSIC data. At the lateral margin, DR showed average agreement values within 0.3% of simulation at 100 Gy/s and fluctuations ∼10% at 15 Gy/s. LET spectra in the proximal, lateral, and distal margins had Bhattacharyya distances of

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyLinear Energy TransferRadiotherapy DosageRadiation DosageRadiotherapy Planning, Computer-AssistedMonte Carlo Method

Stichwörter der Autor:innen

3D printingFLASH proton therapyTimepix3linear energy transfer (LET)ridge filter

Autor:innen und Institutionen

  • Emory University, Atlanta, Georgia, USA.
  • Stanford University, Stanford, California, USA.
  • ADVACAM s.r.o., Prague, Czech Republic.
  • Georgia Institute of Technology, Atlanta, Georgia, USA.
  • Washington University of St. Louis, Saint Louis, Missouri, USA.

Zitieren

APA

Harrison, N., Charyyev, S., Oancea, C., Stanforth, A., Gelover, E., Zhou, S., Dynan, W. S., Zhang, T., Biegalski, S., & Lin, L. (2024). Characterizing devices for validation of dose, dose rate, and LET in ultra high dose rate proton irradiations. Medical Physics. https://doi.org/10.1002/mp.17359

Vancouver

Harrison N, Charyyev S, Oancea C, Stanforth A, Gelover E, Zhou S, et al. Characterizing devices for validation of dose, dose rate, and LET in ultra high dose rate proton irradiations. Medical Physics. 2024. doi:10.1002/mp.17359

BibTeX
@article{Harrison2024,
  author = {Harrison, Nathan and Charyyev, Serdar and Oancea, Cristina and Stanforth, Alexander and Gelover, Edgar and Zhou, Shuang and Dynan, William S and Zhang, Tiezhi and Biegalski, Steven and Lin, Liyong},
  title = {Characterizing devices for validation of dose, dose rate, and LET in ultra high dose rate proton irradiations},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.17359}
}
Kostenlos starten →