Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Mansure Schafasand und 8 weiteren Autor:innen. Beteiligte Einrichtung: MedAustron Ion Therapy Center, Wiener Neustadt, Austria. Hauptthemen laut MEDLINE: Heavy Ion Radiotherapy, Proton Therapy. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The increasing number of studies dealing with linear energy transfer (LET)‐based evaluation and optimization in the field of carbon ion radiotherapy (CIRT) indicates the rising demand for LET implementation in commercial treatment planning systems (TPS). Benchmarking studies could play a key role in detecting (and thus preventing) computation errors prior implementing such functionalities in a TPS.
Purpose
This in silico study was conducted to benchmark the following two LET‐related functionalities in a commercial TPS against Monte Carlo simulations: (1) dose averaged LET (LET d ) scoring and (2) physical dose filtration based on LET for future LET‐based treatment plan evaluation and optimization studies.
Methods
The LET d scoring and LET‐based dose filtering (in which the deposited dose can be separated into the dose below and above the user specified LET threshold) functionalities for carbon ions in the research version RayStation (RS) 9A‐IonPG TPS (RaySearch Laboratories, Sweden) were benchmarked against GATE/Geant4 simulations. Pristine Bragg peaks (BPs) and cuboid targets, positioned at different depths in a homogeneous water phantom and a setup with heterogeneity were used for this study.
Results
For all setups (homogeneous and heterogeneous), the mean absolute (and relative) LET d difference was less than 1 keV/m (3.5%) in the plateau and target and less than 2 keV/m (8.3%) in the fragmentation tail. The maximum local differences were 4 and 6 keV/m, respectively. The mean absolute (and relative) physical dose differences for both low‐ and high‐LET doses were less than 1 cGy (1.5%) in the plateau, target and tail with a maximum absolute difference of 2 cGy.
Conclusions
No computation error was found in the tested functionalities except for LET d in lateral direction outside the target, showing the limitation of the implemented monochrome model in the tested TPS version.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- MedAustron Ion Therapy Center, Wiener Neustadt, Austria.
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
- RaySearch Laboratories AB, Stockholm, Sweden.
- Department of Oncology, Karl Landsteiner University of Health Sciences, Krems an der Donau, Austria.
Zitieren
APA
Schafasand, M., Resch, A. F., Traneus, E., Glimelius, L., Fossati, P., Stock, M., Gora, J., Georg, D., & Carlino, A. (2023). Technical note: In silico benchmarking of the linear energy transfer‐based functionalities for carbon ion beams in a commercial treatment planning system. Medical Physics. https://doi.org/10.1002/mp.16174
Vancouver
Schafasand M, Resch AF, Traneus E, Glimelius L, Fossati P, Stock M, et al. Technical note: In silico benchmarking of the linear energy transfer‐based functionalities for carbon ion beams in a commercial treatment planning system. Medical Physics. 2023. doi:10.1002/mp.16174
BibTeX
@article{Schafasand2023,
author = {Schafasand, Mansure and Resch, Andreas Franz and Traneus, Erik and Glimelius, Lars and Fossati, Piero and Stock, Markus and Gora, Joanna and Georg, Dietmar and Carlino, Antonio},
title = {Technical note: In silico benchmarking of the linear energy transfer‐based functionalities for carbon ion beams in a commercial treatment planning system},
journal = {Medical Physics},
year = {2023},
doi = {10.1002/mp.16174}
}
EUVIMED