EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A unified generation‐registration framework for improved MR‐based CT synthesis in proton therapy

Xia Li iD, Renato Bellotti, Barbara Bachtiary, Jan Hrbacek, Damien C Weber, Antony J Lomax, Joachim M Buhmann, Ye Zhang

Medical Physics · 2024

DOI: 10.1002/mp.17338 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Xia Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland. Hauptthemen laut MEDLINE: Proton Therapy, Magnetic Resonance Imaging, Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: PHRT, EU-H2020 INSPIRE.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The use of magnetic resonance (MR) imaging for proton therapy treatment planning is gaining attention as a highly effective method for guidance. At the core of this approach is the generation of computed tomography (CT) images from MR scans. However, the critical issue in this process is accurately aligning the MR and CT images, a task that becomes particularly challenging in frequently moving body areas, such as the head‐and‐neck. Misalignments in these images can result in blurred synthetic CT (sCT) images, adversely affecting the precision and effectiveness of the treatment planning.

Purpose

This study introduces a novel network that cohesively unifies image generation and registration processes to enhance the quality and anatomical fidelity of sCTs derived from better‐aligned MR images.

Methods

The approach synergizes a generation network (G) with a deformable registration network (R), optimizing them jointly in MR‐to‐CT synthesis. This goal is achieved by alternately minimizing the discrepancies between the generated/registered CT images and their corresponding reference CT counterparts. The generation network employs a UNet architecture, while the registration network leverages an implicit neural representation (INR) of the displacement vector fields (DVFs). We validated this method on a dataset comprising 60 head‐and‐neck patients, reserving 12 cases for holdout testing.

Results

Compared to the baseline Pix2Pix method with MAE 124.9530.74 HU, the proposed technique demonstrated 80.987.55 HU. The unified translation‐registration network produced sharper and more anatomically congruent outputs, showing superior efficacy in converting MR images to sCTs. Additionally, from a dosimetric perspective, the plan recalculated on the resulting sCTs resulted in a remarkably reduced discrepancy to the reference proton plans.

Conclusions

This study conclusively demonstrates that a holistic MR‐based CT synthesis approach, integrating both image‐to‐image translation and deformable registration, significantly improves the precision and quality of sCT generation, particularly for the challenging body area with varied anatomic changes between corresponding MR and CT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyMagnetic Resonance ImagingTomography, X-Ray ComputedImage Processing, Computer-AssistedHumansRadiotherapy Planning, Computer-AssistedHead and Neck NeoplasmsRadiotherapy, Image-Guided

Stichwörter der Autor:innen

MR‐to‐CT synthesisdeformable registrationhead‐and‐neckimplicit neural representationnnUnetproton therapy

Autor:innen und Institutionen

  • Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland.
  • Department of Computer Science, ETH Zürich, Zürich, Switzerland.
  • Department of Physics, ETH Zürich, Zürich, Switzerland.
  • Department of Radiation Oncology, University Hospital of Zürich, Zürich, Switzerland.
  • Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

ORCID-Profile: Xia Li

Förderung

  • PHRT
  • EU-H2020 INSPIRE

Zitieren

APA

Li, X., Bellotti, R., Bachtiary, B., Hrbacek, J., Weber, D. C., Lomax, A. J., Buhmann, J. M., & Zhang, Y. (2024). A unified generation‐registration framework for improved MR‐based CT synthesis in proton therapy. Medical Physics. https://doi.org/10.1002/mp.17338

Vancouver

Li X, Bellotti R, Bachtiary B, Hrbacek J, Weber DC, Lomax AJ, et al. A unified generation‐registration framework for improved MR‐based CT synthesis in proton therapy. Medical Physics. 2024. doi:10.1002/mp.17338

BibTeX
@article{Li2024,
  author = {Li, Xia and Bellotti, Renato and Bachtiary, Barbara and Hrbacek, Jan and Weber, Damien C and Lomax, Antony J and Buhmann, Joachim M and Zhang, Ye},
  title = {A unified generation‐registration framework for improved MR‐based CT synthesis in proton therapy},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.17338}
}
Kostenlos starten →