Radiomic feature robustness in CT scans affected by fiducial marker induced streak artifacts for patients with hepatocellular carcinoma
Medical Physics · 2024
DOI: 10.1002/mp.17329 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Damon Verstappen und 4 weiteren Autor:innen. Beteiligte Einrichtung: The D-Lab, Department of Precision Medicine, GROW School for Oncology and Reproduction, Maastricht University, Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Liver Neoplasms, Fiducial Markers, Carcinoma, Hepatocellular, Artifacts. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Stereotactic body radiation therapy for hepatocellular carcinoma necessitates the implantation of gold fiducial markers in the liver, resulting in artifacts on computed tomography (CT) scans, which affect radiomic feature values.
Purpose
This report aims to assess the effect of these artifacts on radiomic features and how removing CT slices affects radiomic features extracted from 3D regions of interest (ROI).
Methods
First, the range variation in 38 tumor contours unaffected by artifacts was assessed after sequentially and randomly removing 25%, 50%, 75% of slices. Subsequently, the agreement of feature values before and after removing ROI slices containing artifacts from 186 patients’ CT scans was assessed with Lin's concordance correlation coefficient (CCC) and a Wilcoxon signed‐rank test.
Results
In artifact‐free tumor volumes, at least 71% of features remain robust with up to 50% of slices removed, while 56% remains robust with up to 75% of slices removed. When comparing contours before and after removing slices containing artifacts, around a third of features in the tumor contour and surrounding area remain robust (CCC > 0.9), compared to 44% in the healthy liver. Concerning the tumor, 13% (Gray Level Size Zone Matrix) to 61% (first order) of the features remain robust (CCC > 0.9). Over 90% of features differ significantly as assessed by Wilcoxon signed‐rank test, however.
Conclusions
This study demonstrates that removing slices containing artifacts is a feasible solution for the CT fiducial problem in this patient population and provides insight into which features are affected.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The D-Lab, Department of Precision Medicine, GROW School for Oncology and Reproduction, Maastricht University, Maastricht, The Netherlands.
- Academic Department of Radiation Oncology, Centre Oscar Lambret, Lille, France.
- CNRS, Centrale Lille, UMR 9189 - CRIStAL, Univ. Lille, Lille, France.
- Department of Radiology and Nuclear Medicine, GROW School for Oncology and Reproduction, Maastricht University Medical Center+, Maastricht, The Netherlands.
Zitieren
APA
Verstappen, D., Pasquier, D., Chen, Y., Lambin, P., & Woodruff, H. C. (2024). Radiomic feature robustness in CT scans affected by fiducial marker induced streak artifacts for patients with hepatocellular carcinoma. Medical Physics. https://doi.org/10.1002/mp.17329
Vancouver
Verstappen D, Pasquier D, Chen Y, Lambin P, Woodruff HC. Radiomic feature robustness in CT scans affected by fiducial marker induced streak artifacts for patients with hepatocellular carcinoma. Medical Physics. 2024. doi:10.1002/mp.17329
BibTeX
@article{Verstappen2024,
author = {Verstappen, Damon and Pasquier, David and Chen, Yi and Lambin, Phillipe and Woodruff, Henry C},
title = {Radiomic feature robustness in CT scans affected by fiducial marker induced streak artifacts for patients with hepatocellular carcinoma},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.17329}
}
EUVIMED