EUVIMEDScopri EUVIMED
Open access

CBCT‐based synthetic CT image generation using a diffusion model for CBCT‐guided lung radiotherapy

Xiaoqian Chen, Richard L J Qiu, Junbo Peng, Joseph W Shelton, Chih-Wei Chang, Xiaofeng Yang, Aparna H Kesarwala

Medical Physics · 2024-11 · 51 (11) · 8168-8178

DOI: 10.1002/mp.17328 ↗

At a glance

Journal article in Medical Physics, 2024-08. Written by Xiaoqian Chen and 6 co-authors. Institution: Department of Radiation Oncology, Winship Cancer Institute, Emory University School of Medicine, Atlanta, Georgia, USA. Major MEDLINE topics: Cone-Beam Computed Tomography, Radiotherapy, Image-Guided, Lung Neoplasms, Image Processing, Computer-Assisted. Cited 31 times so far (Crossref); 56 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Although cone beam computed tomography (CBCT) has lower resolution compared to planning CTs (pCT), its lower dose, higher high‐contrast resolution, and shorter scanning time support its widespread use in clinical applications, especially in ensuring accurate patient positioning during the image‐guided radiation therapy (IGRT) process.

Purpose

While CBCT is critical to IGRT, CBCT image quality can be compromised by severe stripe and scattering artifacts. Tumor movement secondary to respiratory motion also decreases CBCT resolution. In order to improve the image quality of CBCT, we propose a Lung Diffusion Model (L‐DM) framework.

Methods

Our proposed algorithm is based on a conditional diffusion model trained on pCT and deformed CBCT (dCBCT) image pairs to synthesize lung CT images from dCBCT images and benefit CBCT‐based radiotherapy. dCBCT images were used as the constraint for the L‐DM. The image quality and Hounsfield unit (HU) values of the synthetic CTs (sCT) images generated by the proposed L‐DM were compared to three selected mainstream generation models.

Results

We verified our model in both an institutional lung cancer dataset and a selected public dataset. Our L‐DM showed significant improvement in the four metrics of mean absolute error (MAE), peak signal‐to‐noise ratio (PSNR), normalized cross‐correlation (NCC), and structural similarity index measure (SSIM). In our institutional dataset, our proposed L‐DM decreased the MAE from 101.47 to 37.87 HU and increased the PSNR from 24.97 to 29.89 dB, the NCC from 0.81 to 0.97, and the SSIM from 0.80 to 0.93. In the public dataset, our proposed L‐DM decreased the MAE from 173.65 to 58.95 HU, while increasing the PSNR, NCC, and SSIM from 13.07 to 24.05 dB, 0.68 to 0.94, and 0.41 to 0.88, respectively.

Conclusions

The proposed L‐DM significantly improved sCT image quality compared to the pre‐correction CBCT and three mainstream generative models. Our model can benefit CBCT‐based IGRT and other potential clinical applications as it increases the HU accuracy and decreases the artifacts from input CBCT images.

Subjects

MeSH terms (MEDLINE)

Cone-Beam Computed TomographyRadiotherapy, Image-GuidedLung NeoplasmsImage Processing, Computer-AssistedHumansDiffusionLungAlgorithms

Author keywords

CBCTdiffusion modelimage synthesislung cancersynthetic CT

Authors and institutions

  • Department of Radiation Oncology, Winship Cancer Institute, Emory University School of Medicine, Atlanta, Georgia, USA.

Funding

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Cite

APA

Chen, X., Qiu, R. L. J., Peng, J., Shelton, J. W., Chang, C. W., Yang, X., & Kesarwala, A. H. (2024). CBCT‐based synthetic CT image generation using a diffusion model for CBCT‐guided lung radiotherapy. Medical Physics, 51(11), 8168-8178. https://doi.org/10.1002/mp.17328

Vancouver

Chen X, Qiu RLJ, Peng J, Shelton JW, Chang CW, Yang X, et al. CBCT‐based synthetic CT image generation using a diffusion model for CBCT‐guided lung radiotherapy. Medical Physics. 2024;51(11):8168-8178. doi:10.1002/mp.17328

BibTeX
@article{Chen2024,
  author = {Chen, Xiaoqian and Qiu, Richard L J and Peng, Junbo and Shelton, Joseph W and Chang, Chih-Wei and Yang, Xiaofeng and Kesarwala, Aparna H},
  title = {CBCT‐based synthetic CT image generation using a diffusion model for CBCT‐guided lung radiotherapy},
  journal = {Medical Physics},
  year = {2024},
  volume = {51},
  number = {11},
  pages = {8168--8178},
  doi = {10.1002/mp.17328}
}