EUVIMEDOpdag EUVIMED
Crossref

Squeeze‐and‐excitation‐attention‐based mobile vision transformer for grading recognition of bladder prolapse in pelvic MRI images

Shaojun Zhu, Guotao Chen, Hongguang Chen, Ying Lu, Maonian Wu, Bo Zheng, Dongquan Liu, Cheng Qian, Yun Chen

Medical Physics · 2024-08 · 51 (8) · 5236-5249

DOI: 10.1002/mp.17171 ↗

At a glance

Journal article in Medical Physics, published online on 2024-05-20. Written by Shaojun Zhu and 8 co-authors. Institution: School of information engineering, Huzhou University, Huzhou, Zhejiang, China. Major MEDLINE topics: Magnetic Resonance Imaging. Cited 9 times so far (Crossref); 43 references. Funded by: National Natural Science Foundation of China, Natural Science Foundation of Zhejiang Province, Ningbo Medical Science and Technology Plan Project.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Bladder prolapse is a common clinical disorder of pelvic floor dysfunction in women, and early diagnosis and treatment can help them recover. Pelvic magnetic resonance imaging (MRI) is one of the most important methods used by physicians to diagnose bladder prolapse; however, it is highly subjective and largely dependent on the clinical experience of physicians. The application of computer‐aided diagnostic techniques to achieve a graded diagnosis of bladder prolapse can help improve its accuracy and shorten the learning curve.

Purpose

The purpose of this study is to combine convolutional neural network (CNN) and vision transformer (ViT) for grading bladder prolapse in place of traditional neural networks, and to incorporate attention mechanisms into mobile vision transformer (MobileViT) for assisting in the grading of bladder prolapse.

Methods

This study focuses on the grading of bladder prolapse in pelvic organs using a combination of a CNN and a ViT. First, this study used MobileNetV2 to extract the local features of the images. Next, a ViT was used to extract the global features by modeling the non‐local dependencies at a distance. Finally, a channel attention module (i.e., squeeze‐and‐excitation network) was used to improve the feature extraction network and enhance its feature representation capability. The final grading of the degree of bladder prolapse was thus achieved.

Results

Using pelvic MRI images provided by a Huzhou Maternal and Child Health Care Hospital, this study used the proposed method to grade patients with bladder prolapse. The accuracy, Kappa value, sensitivity, specificity, precision, and area under the curve of our method were 86.34%, 78.27%, 83.75%, 95.43%, 85.70%, and 95.05%, respectively. In comparison with other CNN models, the proposed method performed better.

Conclusions

Thus, the model based on attention mechanisms exhibits better classification performance than existing methods for grading bladder prolapse in pelvic organs, and it can effectively assist physicians in achieving a more accurate bladder prolapse diagnosis.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingHumansFemaleNeural Networks, ComputerImage Processing, Computer-AssistedPelvisUrinary Bladder Diseases

Author keywords

attention mechanismbladder prolapseconvolutional neural networkmedical image classificationpelvic organsvision transformer

Authors and institutions

  • School of information engineering, Huzhou University, Huzhou, Zhejiang, China.
  • Zhejiang Province Key Laboratory of Smart Management & Application of Modern Agricultural 8 Resources, Huzhou University, Huzhou, China.
  • Ninghai First Hospital, Ninghai, Zhejiang, China.
  • Department of Colon-rectal Surgery, Huzhou Maternity & Child Health Care Hospital, Huzhou, China.

Funding

  • National Natural Science Foundation of China
  • Natural Science Foundation of Zhejiang Province
  • Ningbo Medical Science and Technology Plan Project
  • Ningbo Public Welfare Fund Project
  • Ninghai Social Development Science and Technology Plan Project
  • Scientific Research Fund of Zhejiang Provincial Education Department
  • Postgraduate Research and Innovation Project of Huzhou University

Cite

APA

Zhu, S., Chen, G., Chen, H., Lu, Y., Wu, M., Zheng, B., Liu, D., Qian, C., & Chen, Y. (2024). Squeeze‐and‐excitation‐attention‐based mobile vision transformer for grading recognition of bladder prolapse in pelvic MRI images. Medical Physics, 51(8), 5236-5249. https://doi.org/10.1002/mp.17171

Vancouver

Zhu S, Chen G, Chen H, Lu Y, Wu M, Zheng B, et al. Squeeze‐and‐excitation‐attention‐based mobile vision transformer for grading recognition of bladder prolapse in pelvic MRI images. Medical Physics. 2024;51(8):5236-5249. doi:10.1002/mp.17171

BibTeX
@article{Zhu2024,
  author = {Zhu, Shaojun and Chen, Guotao and Chen, Hongguang and Lu, Ying and Wu, Maonian and Zheng, Bo and Liu, Dongquan and Qian, Cheng and Chen, Yun},
  title = {Squeeze‐and‐excitation‐attention‐based mobile vision transformer for grading recognition of bladder prolapse in pelvic MRI images},
  journal = {Medical Physics},
  year = {2024},
  volume = {51},
  number = {8},
  pages = {5236--5249},
  doi = {10.1002/mp.17171}
}