Automated multiclass segmentation, quantification, and visualization of the diseased aorta on hybrid PET/CT–SEQUOIA
Medical Physics · 2024-06 · 51 (6) · 4297-4310
DOI: 10.1002/mp.16967 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 07.02.2024. Verfasst von Gijs D van Praagh und 15 weiteren Autor:innen. Beteiligte Einrichtung: Medical Imaging Center, Department of Nuclear Medicine & Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, …. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Image Processing, Computer-Assisted, Automation. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council.
Abstract (Originalsprache)
Background
Cardiovascular disease is the most common cause of death worldwide, including infection and inflammation related conditions. Multiple studies have demonstrated potential advantages of hybrid positron emission tomography combined with computed tomography (PET/CT) as an adjunct to current clinical inflammatory and infectious biochemical markers. To quantitatively analyze vascular diseases at PET/CT, robust segmentation of the aorta is necessary. However, manual segmentation is extremely time‐consuming and labor‐intensive.
Purpose
To investigate the feasibility and accuracy of an automated tool to segment and quantify multiple parts of the diseased aorta on unenhanced low‐dose computed tomography (LDCT) as an anatomical reference for PET‐assessed vascular disease.
Methods
A software pipeline was developed including automated segmentation using a 3D U‐Net, calcium scoring, PET uptake quantification, background measurement, radiomics feature extraction, and 2D surface visualization of vessel wall calcium and tracer uptake distribution. To train the 3D U‐Net, 352 non‐contrast LDCTs from (2‐[ 18 F]FDG and Na[ 18 F]F) PET/CTs performed in patients with various vascular pathologies with manual segmentation of the ascending aorta, aortic arch, descending aorta, and abdominal aorta were used. The last 22 consecutive scans were used as a hold‐out internal test set. The remaining dataset was randomly split into training ( n = 264; 80%) and validation ( n = 66; 20%) sets. Further evaluation was performed on an external test set of 49 PET/CTs. The dice similarity coefficient (DSC) and Hausdorff distance (HD) were used to assess segmentation performance. Automatically obtained calcium scores and uptake values were compared with manual scoring obtained using clinical softwares ( syngo .via and Affinity Viewer) in six patient images. intraclass correlation coefficients (ICC) were calculated to validate calcium and uptake values.
Results
Fully automated segmentation of the aorta using a 3D U‐Net was feasible in LDCT obtained from PET/CT scans. The external test set yielded a DSC of 0.867 ± 0.030 and HD of 1.0 [0.6–1.4] mm, similar to an open‐source model with a DSC of 0.864 ± 0.023 and HD of 1.4 [1.0–1.8] mm. Quantification of calcium and uptake values were in excellent agreement with clinical software (ICC: 1.00 [1.00–1.00] and 0.99 [0.93–1.00] for calcium and uptake values, respectively).
Conclusions
We present an automated pipeline to segment the ascending aorta, aortic arch, descending aorta, and abdominal aorta on LDCT from PET/CT and to accurately provide uptake values, calcium scores, background measurement, radiomics features, and a 2D visualization. We call this algorithm SEQUOIA (SEgmentation, QUantification, and visualizatiOn of the dIseased Aorta) and is available at https://github.com/UMCG‐CVI/SEQUOIA . This model could augment the utility of aortic evaluation at PET/CT studies tremendously, irrespective of the tracer, and potentially provide fast and reliable quantification of cardiovascular diseases in clinical practice, both for primary diagnosis and disease monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Imaging Center, Department of Nuclear Medicine & Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
- Department of Internal Medicine, division of Vascular Medicine, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
- Department of Applied Mathematics and Technical Medicine Center, University of Twente, Enschede, the Netherlands.
- Faculty of Engineering and Physical Sciences, University of Leeds, Leeds, UK.
- Siemens Medical Solutions USA, Inc., Knoxville, Tennessee, USA.
- University of Leeds, School of Medicine, Leeds, UK.
Förderung
- Medical Research Council
Zitieren
APA
van Praagh, G. D., Nienhuis, P. H., Reijrink, M., Davidse, M. E. J., Duff, L. M., Spottiswoode, B. S., Mulder, D. J., Prakken, N. H. J., Scarsbrook, A. F., Morgan, A. W., Tsoumpas, C., Wolterink, J. M., Mouridsen, K. B., Borra, R. J. H., Sinha, B., & Slart, R. H. J. A. (2024). Automated multiclass segmentation, quantification, and visualization of the diseased aorta on hybrid PET/CT–SEQUOIA. Medical Physics, 51(6), 4297-4310. https://doi.org/10.1002/mp.16967
Vancouver
van Praagh GD, Nienhuis PH, Reijrink M, Davidse MEJ, Duff LM, Spottiswoode BS, et al. Automated multiclass segmentation, quantification, and visualization of the diseased aorta on hybrid PET/CT–SEQUOIA. Medical Physics. 2024;51(6):4297-4310. doi:10.1002/mp.16967
BibTeX
@article{vanPraagh2024,
author = {van Praagh, Gijs D and Nienhuis, Pieter H and Reijrink, Melanie and Davidse, Mirjam E J and Duff, Lisa M and Spottiswoode, Bruce S and Mulder, Douwe J and Prakken, Niek H J and Scarsbrook, Andy F and Morgan, Ann W and Tsoumpas, Charalampos and Wolterink, Jelmer M and Mouridsen, Kim B and Borra, Ronald J H and Sinha, Bhanu and Slart, Riemer H J A},
title = {Automated multiclass segmentation, quantification, and visualization of the diseased aorta on hybrid PET/CT–SEQUOIA},
journal = {Medical Physics},
year = {2024},
volume = {51},
number = {6},
pages = {4297--4310},
doi = {10.1002/mp.16967}
}
EUVIMED