EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

vOARiability: Interobserver and intermodality variability analysis in OAR contouring from head and neck CT and MR images

Gašper Podobnik, Bulat Ibragimov, Primož Peterlin, Primož Strojan, Tomaž Vrtovec

Medical Physics · 2024

DOI: 10.1002/mp.16924 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Gašper Podobnik und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Head and Neck Neoplasms. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Slovenian Research and Innovation Agency (ARIS), Novo Nordisk Fonden, Ethics Committee of the Institute of Oncology Ljubljana, Slovenia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate and consistent contouring of organs‐at‐risk (OARs) from medical images is a key step of radiotherapy (RT) cancer treatment planning. Most contouring approaches rely on computed tomography (CT) images, but the integration of complementary magnetic resonance (MR) modality is highly recommended, especially from the perspective of OAR contouring, synthetic CT and MR image generation for MR‐only RT, and MR‐guided RT. Although MR has been recognized as valuable for contouring OARs in the head and neck (HaN) region, the accuracy and consistency of the resulting contours have not been yet objectively evaluated.

Purpose

To analyze the interobserver and intermodality variability in contouring OARs in the HaN region, performed by observers with different level of experience from CT and MR images of the same patients.

Methods

In the final cohort of 27 CT and MR images of the same patients, contours of up to 31 OARs were obtained by a radiation oncology resident (junior observer, JO) and a board‐certified radiation oncologist (senior observer, SO). The resulting contours were then evaluated in terms of interobserver variability, characterized as the agreement among different observers (JO and SO) when contouring OARs in a selected modality (CT or MR), and intermodality variability, characterized as the agreement among different modalities (CT and MR) when OARs were contoured by a selected observer (JO or SO), both by the Dice coefficient (DC) and 95‐percentile Hausdorff distance (HD ).

Results

The mean (±standard deviation) interobserver variability was 69.0 ± 20.2% and 5.1 ± 4.1 mm, while the mean intermodality variability was 61.6 ± 19.0% and 6.1 ± 4.3 mm in terms of DC and HD , respectively, across all OARs. Statistically significant differences were only found for specific OARs. The performed MR to CT image registration resulted in a mean target registration error of 1.7 ± 0.5 mm, which was considered as valid for the analysis of intermodality variability.

Conclusions

The contouring variability was, in general, similar for both image modalities, and experience did not considerably affect the contouring performance. However, the results indicate that an OAR is difficult to contour regardless of whether it is contoured in the CT or MR image, and that observer experience may be an important factor for OARs that are deemed difficult to contour. Several of the differences in the resulting variability can be also attributed to adherence to guidelines, especially for OARs with poor visibility or without distinctive boundaries in either CT or MR images. Although considerable contouring differences were observed for specific OARs, it can be concluded that almost all OARs can be contoured with a similar degree of variability in either the CT or MR modality, which works in favor of MR images from the perspective of MR‐only and MR‐guided RT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedHead and Neck NeoplasmsHumansNeckTomography, X-Ray ComputedMagnetic Resonance ImagingHeadOrgans at RiskObserver Variation

Stichwörter der Autor:innen

computed tomographycontouringhead and neck cancerimage segmentationmagnetic resonanceorgans-at-riskradiotherapyvariability analysis

Autor:innen und Institutionen

  • Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia.
  • Department of Computer Science, University of Copenhagen, Copenhagen, Denmark.
  • Institute of Oncology Ljubljana, Ljubljana, Slovenia.

Förderung

  • Slovenian Research and Innovation Agency (ARIS)
  • Novo Nordisk Fonden
  • Ethics Committee of the Institute of Oncology Ljubljana, Slovenia

Zitieren

APA

Podobnik, G., Ibragimov, B., Peterlin, P., Strojan, P., & Vrtovec, T. (2024). vOARiability: Interobserver and intermodality variability analysis in OAR contouring from head and neck CT and MR images. Medical Physics. https://doi.org/10.1002/mp.16924

Vancouver

Podobnik G, Ibragimov B, Peterlin P, Strojan P, Vrtovec T. vOARiability: Interobserver and intermodality variability analysis in OAR contouring from head and neck CT and MR images. Medical Physics. 2024. doi:10.1002/mp.16924

BibTeX
@article{Podobnik2024,
  author = {Podobnik, Gašper and Ibragimov, Bulat and Peterlin, Primož and Strojan, Primož and Vrtovec, Tomaž},
  title = {vOARiability: Interobserver and intermodality variability analysis in OAR contouring from head and neck CT and MR images},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.16924}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche