EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

CT number calibration audit in photon radiation therapy

Minoru Nakao, Shuichi Ozawa, Hideharu Miura, Kiyoshi Yamada, Masahiro Hayata, Kosuke Hayashi, Daisuke Kawahara, Takeo Nakashima, Yusuke Ochi, Takuro Okumura, Haruhide Kunimoto, Atsushi Kawakubo und 16 weitere

Medical Physics · 2024

DOI: 10.1002/mp.16887 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Minoru Nakao und 27 weiteren Autor:innen. Beteiligte Einrichtung: Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Tomography, X-Ray Computed. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Agency for Medical Research and Development (AMED), National Cancer Center Research and Development Fund, Japan Society for the Promotion of Science (JSPS).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Inadequate computed tomography (CT) number calibration curves affect dose calculation accuracy. Although CT number calibration curves registered in treatment planning systems (TPSs) should be consistent with human tissues, it is unclear whether adequate CT number calibration is performed because CT number calibration curves have not been assessed for various types of CT number calibration phantoms and TPSs.

Purpose

The purpose of this study was to investigate CT number calibration curves for mass density ( ρ ) and relative electron density ( ρ e ).

Methods

A CT number calibration audit phantom was sent to 24 Japanese photon therapy institutes from the evaluating institute and scanned using their individual clinical CT scan protocols. The CT images of the audit phantom and institute‐specific CT number calibration curves were submitted to the evaluating institute for analyzing the calibration curves registered in the TPSs at the participating institutes. The institute‐specific CT number calibration curves were created using commercial phantom (Gammex, Gammex Inc., Middleton, WI, USA) or CIRS phantom (Computerized Imaging Reference Systems, Inc., Norfolk, VA, USA)). At the evaluating institute, theoretical CT number calibration curves were created using a stoichiometric CT number calibration method based on the CT image, and the institute‐specific CT number calibration curves were compared with the theoretical calibration curve. Differences in ρ and ρ e over the multiple points on the curve (Δ ρ m and Δ ρ e,m , respectively) were calculated for each CT number, categorized for each phantom vendor and TPS, and evaluated for three tissue types: lung, soft tissues, and bones. In particular, the CT‐ ρ calibration curves for Tomotherapy TPSs (ACCURAY, Sunnyvale, CA, USA) were categorized separately from the Gammex CT‐ ρ calibration curves because the available tissue‐equivalent materials (TEMs) were limited by the manufacturer recommendations. In addition, the differences in ρ and ρ e for the specific TEMs (Δ ρ TEM and Δ ρ e,TEM , respectively) were calculated by subtracting the ρ or ρ e of the TEMs from the theoretical CT‐ ρ or CT‐ ρ e calibration curve.

Results

The mean ± standard deviation (SD) of Δ ρ m and Δ ρ e,m for the Gammex phantom were −1.1 ± 1.2 g/cm 3 and −0.2 ± 1.1, −0.3 ± 0.9 g/cm 3 and 0.8 ± 1.3, and −0.9 ± 1.3 g/cm 3 and 1.0 ± 1.5 for lung, soft tissues, and bones, respectively. The mean ± SD of Δ ρ m and Δ ρ e,m for the CIRS phantom were 0.3 ± 0.8 g/cm 3 and 0.9 ± 0.9, 0.6 ± 0.6 g/cm 3 and 1.4 ± 0.8, and 0.2 ± 0.5 g/cm 3 and 1.6 ± 0.5 for lung, soft tissues, and bones, respectively. The mean ± SD of Δ ρ m for Tomotherapy TPSs was 2.1 ± 1.4 g/cm 3 for soft tissues, which is larger than those for other TPSs. The mean ± SD of Δ ρ e,TEM for the Gammex brain phantom (BRN‐SR2) was −1.8 ± 0.4, implying that the tissue equivalency of the BRN‐SR2 plug was slightly inferior to that of other plugs.

Conclusions

Latent deviations between human tissues and TEMs were found by comparing the CT number calibration curves of the various institutes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansCalibrationHeadBone and BonesPhantoms, Imaging

Stichwörter der Autor:innen

CT calibrationauditphoton radiation therapyquality assurancestoichiometric method

Autor:innen und Institutionen

  • Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.
  • Department of Radiation Oncology, Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Technical Support Working Group in Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.
  • Medical Physics Working Group in Japan Clinical Oncology Group - Radiation Therapy Study Group, Tokyo, Japan.
  • Radiation Therapy Section, Department of Clinical Support, Hiroshima University Hospital, Hiroshima, Japan.
  • Radiation Therapy Department, Hiroshima Prefectural Hospital, Hiroshima, Japan.

Förderung

  • Japan Agency for Medical Research and Development (AMED)
  • National Cancer Center Research and Development Fund
  • Japan Society for the Promotion of Science (JSPS)

Zitieren

APA

Nakao, M., Ozawa, S., Miura, H., Yamada, K., Hayata, M., Hayashi, K., Kawahara, D., Nakashima, T., Ochi, Y., Okumura, T., Kunimoto, H., Kawakubo, A., Kusaba, H., Nozaki, H., Habara, K., Tohyama, N., Nishio, T., Nakamura, M., Minemura, T., …, & Nagata, Y. (2024). CT number calibration audit in photon radiation therapy. Medical Physics. https://doi.org/10.1002/mp.16887

Vancouver

Nakao M, Ozawa S, Miura H, Yamada K, Hayata M, Hayashi K, et al. CT number calibration audit in photon radiation therapy. Medical Physics. 2024. doi:10.1002/mp.16887

BibTeX
@article{Nakao2024,
  author = {Nakao, Minoru and Ozawa, Shuichi and Miura, Hideharu and Yamada, Kiyoshi and Hayata, Masahiro and Hayashi, Kosuke and Kawahara, Daisuke and Nakashima, Takeo and Ochi, Yusuke and Okumura, Takuro and Kunimoto, Haruhide and Kawakubo, Atsushi and Kusaba, Hayate and Nozaki, Hiroshige and Habara, Kosaku and Tohyama, Naoki and Nishio, Teiji and Nakamura, Mitsuhiro and Minemura, Toshiyuki and Okamoto, Hiroyuki and Ishikawa, Masayori and Kurooka, Masahiko and Shimizu, Hidetoshi and Hotta, Kenji and Saito, Masahide and Nakano, Masahiro and Tsuneda, Masato and Nagata, Yasushi},
  title = {CT number calibration audit in photon radiation therapy},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.16887}
}
Kostenlos starten →