Journal article in Medical Physics, published online on 2023-12-08. Written by Donghyeon Lee and 4 co-authors. Institution: The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Major MEDLINE topics: Tomography, X-Ray Computed, Photons. Cited 4 times so far (Crossref); 25 references. Funded by: Canon Medical Systems Corporation.

ResumoSubjectsDados bibliográficosCiteRelated studies

Abstract (original language)

Background

An energy‐discriminating capability of a photon counting detector (PCD) can provide many clinical advantages, but several factors, such as charge sharing (CS) and pulse pileup (PP), degrade the capability by distorting the measured x‐ray spectrum. To fully exploit the merits of PCDs, it is important to characterize the output of PCDs. Previously proposed PCD output models showed decent agreement with physical PCDs; however, there were still scopes to be improved: a global model–data mismatch and pixel‐to‐pixel variations. Purposes In this study, we improve a PCD model by using count‐rate‐dependent model parameters to address the issues and evaluate agreement against physical PCDs.

Methods

The proposed model is based on the cascaded model, and we made model parameters condition‐dependent and pixel‐specific to deal with the global model–data mismatch and the pixel‐to‐pixel variation. The parameters are determined by a procedure for model parameter estimation with data acquired from different thicknesses of water or aluminum at different x‐ray tube currents. To analyze the effects of having proposed model parameters, we compared three setups of our model: a model with default parameters, a model with global parameters, and a model with global‐and‐local parameters. For experimental validation, we used CdZnTe‐based PCDs, and assessed the performance of the models by calculating the mean absolute percentage errors (MAPEs) between the model outputs and the actual measurements from low count‐rates to high count‐rates, which have deadtime losses of up to 24%.

Results

The outputs of the proposed model visually matched well with the PCD measurements for all test data. For the test data, the MAPEs averaged over all the bins were 49.2–51.1% for a model with default parameters, 8.0–9.8% for a model with the global parameters, and 1.2–2.7% for a model with the global‐and‐local parameters.

Conclusion

The proposed model can estimate the outputs of physical PCDs with high accuracy from low to high count‐rates. We expect that our model will be actively utilized in applications where the pixel‐by‐pixel accuracy of a PCD model is important.

Subjects

MeSH terms (MEDLINE)

Tomography, X-Ray ComputedPhotonsX-Rays

Author keywords

charge sharingcomputed tomographyphoton counting detectorspulse pileup

Authors and institutions

  • The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • The Canon Medical Research USA, Inc., Vernon Hills, Illinois, USA.
  • The Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA.

Funding

  • Canon Medical Systems Corporation

Cite

APA

Lee, D., Zhan, X., Tai, W. Y., Zbijewski, W., & Taguchi, K. (2024). Improving model–data mismatch for photon‐counting detector model using global and local model parameters. Medical Physics, 51(2), 964-977. https://doi.org/10.1002/mp.16883

Vancouver

Lee D, Zhan X, Tai WY, Zbijewski W, Taguchi K. Improving model–data mismatch for photon‐counting detector model using global and local model parameters. Medical Physics. 2024;51(2):964-977. doi:10.1002/mp.16883

BibTeX
@article{Lee2024,
  author = {Lee, Donghyeon and Zhan, Xiaohui and Tai, W Yang and Zbijewski, Wojciech and Taguchi, Katsuyuki},
  title = {Improving model–data mismatch for photon‐counting detector model using global and local model parameters},
  journal = {Medical Physics},
  year = {2024},
  volume = {51},
  number = {2},
  pages = {964--977},
  doi = {10.1002/mp.16883}
}
Start for free →