The impact of (simulated) resolution on breast cancer diagnosis based on high‐resolution 3D micro‐CT microcalcification images

Redona Brahimetaj iD, Jan Cornelis iD, Chantal Van Ongeval iD, Johan De Mey iD, Bart Jansen iD

Medical Physics · 2024

DOI: 10.1002/mp.16708 ↗

At a glance

Journal article in Medical Physics, 2024. Written by Redona Brahimetaj and 4 co-authors. Institution: Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Brussels, Belgium. Major MEDLINE topics: Breast Neoplasms, Breast Diseases, Calcinosis. Cited 4 times so far (Crossref); 26 references. Funded by: Fonds Wetenschappelijk Onderzoek.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Breast microcalcifications (MCs) are considered to be a robust marker of breast cancer. A machine learning model can provide breast cancer diagnosis based on properties of individual MCs ‐ if their characteristics are captured at high resolution and in 3D.

Purpose

The main purpose of the study was to explore the impact of image resolution (8 µm, 16 µm, 32 µm, 64 µm) when diagnosing breast cancer using radiomics features extracted from individual high resolution 3D micro‐CT MC images.

Methods

Breast MCs extracted from 86 female patients were analyzed at four different spatial resolutions: 8 µm (original resolution) and 16 µm, 32 µm, 64 µm (simulated image resolutions). Radiomic features were extracted at each image resolution in an attempt, to find a compact feature signature allowing to distinguish benign and malignant MCs. Machine learning algorithms were used for classifying individual MCs and samples (i.e., patients). For sample diagnosis, a custom‐based thresholding approach was used to combine individual MC results into sample results. We conducted classification experiments when using (a) the same MCs visible in 8 µm, 16 µm, 32 µm, and 64 µm resolution; (b) the same MCs visible in 8 µm, 16 µm, and 32 µm resolution; (c) the same MCs visible in 8 µm and 16 µm resolution; (d) all MCs visible in 8 µm, 16 µm, 32 µm, and 64 µm resolution. Accuracy, sensitivity, specificity, AUC, and F1 score were computed for each experiment.

Results

The individual MC results yielded an accuracy of 77.27%, AUC of 83.83%, F1 score of 77.25%, sensitivity of 80.86%, and specificity of 72.2% at 8 µm resolution. For the individual MC classifications we report for the F1 scores: a 2.29% drop when using 16 µm instead of 8 µm, a 4.01% drop when using 32 µm instead of 8 µm, a 10.69% drop when using 64 µm instead of 8 µm. The sample results yielded an accuracy and F1 score of 81.4%, sensitivity of 80.43%, and specificity value of 82.5% at 8 µm. For the sample classifications we report for F1 score values: a 6.3% drop when using 16 µm instead of 8 µm, a 4.91% drop when using 32 µm instead of 8 µm, and a 6.3% drop when using 64 µm instead of 8 µm.

Conclusions

The highest classification results are obtained at the highest resolution (8 µm). If breast MCs characteristics could be visualized/captured in 3D at a higher resolution compared to what is used nowadays in digital mammograms (approximately 70 µm), breast cancer diagnosis will be improved.

Subjects

MeSH terms (MEDLINE)

Breast NeoplasmsBreast DiseasesCalcinosisFemaleHumansX-Ray MicrotomographyMammography

Author keywords

breast cancerbreast microcalcificationcomputer-aided detection and diagnosis systemsmachine learningmicro-CTradiomicsspatial resolution

Authors and institutions

  • Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Brussels, Belgium.
  • Department of Radiology, Universitair Ziekenhuis Leuven, KU Leuven, Leuven, Belgium.
  • Department of Radiology, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • IMEC, Leuven, Belgium.

ORCID profiles: Redona Brahimetaj, Jan Cornelis, Chantal Van Ongeval, Johan De Mey, Bart Jansen

Funding

  • Fonds Wetenschappelijk Onderzoek

Cite

APA

Brahimetaj, R., Cornelis, J., Van Ongeval, C., De Mey, J., & Jansen, B. (2024). The impact of (simulated) resolution on breast cancer diagnosis based on high‐resolution 3D micro‐CT microcalcification images. Medical Physics. https://doi.org/10.1002/mp.16708

Vancouver

Brahimetaj R, Cornelis J, Van Ongeval C, De Mey J, Jansen B. The impact of (simulated) resolution on breast cancer diagnosis based on high‐resolution 3D micro‐CT microcalcification images. Medical Physics. 2024. doi:10.1002/mp.16708

BibTeX
@article{Brahimetaj2024,
  author = {Brahimetaj, Redona and Cornelis, Jan and Van Ongeval, Chantal and De Mey, Johan and Jansen, Bart},
  title = {The impact of (simulated) resolution on breast cancer diagnosis based on high‐resolution 3D micro‐CT microcalcification images},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.16708}
}
Start for free →