On the passive shimming of a 7 T whole‐body MRI superconducting magnet: Implementation with minimized ferromagnetic materials usage and operable magnetic force control

Wenchen Wang, Yaohui Wang, Hui Wang, Junsheng Cheng, Hongyi Qu, Cong Wang, Chaoqun Niu, Feng Liu

Medical Physics · 2023

DOI: 10.1002/mp.16538 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Wenchen Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Information Technology and Electrical Engineering, University of Queensland, Brisbane, QLD, Australia. Hauptthemen laut MEDLINE: Magnets, Superconductivity. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Science Foundation of China, Natural Science Foundation of Jiangxi, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic field shimming of the magnet is a routine practice in a magnetic resonance imaging (MRI) system. For clinically‐used 1.5 T or 3 T MRI superconducting magnets, it is generally straightforward to achieve desired magnetic field uniformity with the passive shim technique. In comparison, superconducting shims with higher shimming efficiency are usually introduced in combination with passive shimming to satisfy the higher magnetic field uniformity requirement for ultrahigh field magnets (≥7 Tesla). However, superconducting shim usually involves a complex winding structure and low‐temperature environment, bringing considerable engineering challenges and extra costs in practice.

Purpose

In this study, we aimed to improve the passive shimming method that can incorporate the unique electromagnetic properties of ultrahigh‐field MRI magnets and is thus more effective for field corrections at 7T and above.

Methods

In this work, we propose a dedicated passive shimming strategy for a 7 T whole‐body MRI superconducting magnet. In this method, the iron usage and magnetic force due to the iron‐field interaction are strictly managed to ensure a shim tray insert is operable by manpower (without specially designed tools).

Results

To validate the proposed shimming strategy, a shimming experiment was implemented on a 7 T/800 mm superconducting magnet. Alternating with the odd and even shim trays in our two‐round operation, the magnetic field inhomogeneity was successfully corrected from 85.36 to 7.91 ppm, achieving the magnetic field quality elevation of more than one order of magnitude.

Conclusion

The experimental results indicated that the proposed electromagnetic technology is expected to be effective for developing ultrahigh‐field MRI instruments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagnetsSuperconductivityMagnetic Resonance ImagingMagnetic FieldsIron

Stichwörter der Autor:innen

MRImagnetic forcepassive shimmingultra-high field

Substanzen

Iron

Autor:innen und Institutionen

  • School of Information Technology and Electrical Engineering, University of Queensland, Brisbane, QLD, Australia.
  • Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China.
  • Ganjiang Innovation Academy, Chinese Academy of Sciences, Ganzhou, China.
  • College of Information and Communication Engineering, Faculty of Information Technology, Beijing University of Technology, Beijing, China.

Förderung

  • National Key Research and Development Program of China
  • National Science Foundation of China
  • Natural Science Foundation of Jiangxi, China
  • Australian Research Council
  • National Natural Science Foundation of China

Zitieren

APA

Wang, W., Wang, Y., Wang, H., Cheng, J., Qu, H., Wang, C., Niu, C., & Liu, F. (2023). On the passive shimming of a 7 T whole‐body MRI superconducting magnet: Implementation with minimized ferromagnetic materials usage and operable magnetic force control. Medical Physics. https://doi.org/10.1002/mp.16538

Vancouver

Wang W, Wang Y, Wang H, Cheng J, Qu H, Wang C, et al. On the passive shimming of a 7 T whole‐body MRI superconducting magnet: Implementation with minimized ferromagnetic materials usage and operable magnetic force control. Medical Physics. 2023. doi:10.1002/mp.16538

BibTeX
@article{Wang2023,
  author = {Wang, Wenchen and Wang, Yaohui and Wang, Hui and Cheng, Junsheng and Qu, Hongyi and Wang, Cong and Niu, Chaoqun and Liu, Feng},
  title = {On the passive shimming of a 7 T whole‐body MRI superconducting magnet: Implementation with minimized ferromagnetic materials usage and operable magnetic force control},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16538}
}
Kostenlos starten →