EUVIMEDEUVIMED entdecken
Open Access

Interleaved signal multiplexing readout in depth encoding Prism‐PET detectors

Yixin Li, Andy LaBella, Xinjie Zeng, Zipai Wang, Eric Petersen, Xinjie Cao, Wei Zhao, Amir H Goldan

Medical Physics · 2023

DOI: 10.1002/mp.16456 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Yixin Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, College of Engineering and Applied Sciences, Stony Brook University, Stony Brook, New York, USA. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Lutetium. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Given the large number of readout pixels in clinical positron emission tomography (PET) scanners, signal multiplexing is an indispensable feature to reduce scanner complexity, power consumption, heat output, and cost.

Purpose

In this paper, we introduce interleaved multiplexing (iMux) scheme that utilizes the characteristic light‐sharing pattern of depth‐encoding Prism‐PET detector modules with single‐ended readout.

Methods

In the iMux readout, four anodes from every other silicon photomultiplier (SiPM) pixels across rows and columns, which overlap with four distinct light guides, are connected to the same application‐specific integrated circuit (ASIC) channel. The 4‐to‐1 coupled Prism‐PET detector module was used which consisted of a 16 × 16 array of 1.5 × 1.5 × 20 mm 3 lutetium yttrium oxyorthosilicate (LYSO) scintillator crystals coupled to an 8 × 8 array with 3 × 3 mm 2 SiPM pixels. A deep learning‐based demultiplexing model was investigated to recover the encoded energy signals. Two different experiments were performed with non‐multiplexed and multiplexed readouts to evaluate the spatial, depth of interaction (DOI), and timing resolutions of our proposed iMux scheme.

Results

The measured flood histograms, using the decoded energy signals from our deep learning‐based demultiplexing architecture, achieved perfect crystal identification of events with negligible decoding error. The average energy, DOI, and timing resolutions were 9.6 ± 1.5%, 2.9 ± 0.9 mm, and 266 ± 19 ps for non‐multiplexed readout and 10.3 ± 1.6%, 2.8 ± 0.8 mm, and 311 ± 28 ps for multiplexed readout, respectively.

Conclusions

Our proposed iMux scheme improves on the already cost‐effective and high‐resolution Prism‐PET detector module and provides 16‐to‐1 crystal‐to‐readout multiplexing without appreciable performance degradation. Also, only four SiPM pixels are shorted together in the 8 × 8 array to achieve 4‐to‐1 pixel‐to‐readout multiplexing, resulting in lower capacitance per multiplexed channel.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron-Emission TomographyLutetiumSilicatesElectrodes

Stichwörter der Autor:innen

Prism-PETdeep learningdemultiplexingsignal multiplexing

Substanzen

lutetium orthosilicateLutetiumSilicates

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, College of Engineering and Applied Sciences, Stony Brook University, Stony Brook, New York, USA.
  • Department of Radiology, Weill Cornell Medical College, Cornell University, New York, New York, USA.
  • Department of Radiology, Boston Children's Hospital, Boston, Massachusetts, USA.
  • Department of Biomedical Engineering, College of Engineering and Applied Sciences, Stony Brook University, Stony Brook, New York, USA.
  • Department of Radiology, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA.

Förderung

  • NIBIB NIH HHS

Zitieren

APA

Li, Y., LaBella, A., Zeng, X., Wang, Z., Petersen, E., Cao, X., Zhao, W., & Goldan, A. H. (2023). Interleaved signal multiplexing readout in depth encoding Prism‐PET detectors. Medical Physics. https://doi.org/10.1002/mp.16456

Vancouver

Li Y, LaBella A, Zeng X, Wang Z, Petersen E, Cao X, et al. Interleaved signal multiplexing readout in depth encoding Prism‐PET detectors. Medical Physics. 2023. doi:10.1002/mp.16456