Improved accuracy of the biodistribution and internal radiation dosimetry of 13 N‐ammonia using a total‐body PET/CT scanner

Xiaofeng Yu, Hongyan Sun, Lian Xu, Yuan Han, Cheng Wang, Lianghua Li, Yee Ling Ng, Fuxiao Shi, Ju Qiu, Gang Huang, Yun Zhou, Yumei Chen und 1 weitere

Medical Physics · 2023

DOI: 10.1002/mp.16450 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Xiaofeng Yu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Ammonia. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, National key research and development program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Conventional short‐axis PET typically utilizes multi‐bed multi‐pass acquisition to produce quantitative whole‐body dynamic images and cannot record all the uptake information simultaneously, resulting in errors when fitting the time‐activity curves (TACs) and calculating radiation doses.

Purpose

The aim of this study is to evaluate the 13 N‐ammonia biodistribution and the internal radiation doses using a 194 cm long total‐body PET/CT scanner (uEXPLORER), and make a comparison with the previous short‐axis PET results.

Methods

Ten subjects (age 40–74 years) received 13 N‐NH 3 injection (418.1‐670.81 MBq) and were under a dynamic scan for about 60 min with using a 3‐dimensional whole‐body protocol. ROIs were drawn visually on 11 major organs (brain, thyroid, gallbladder, heart wall, kidneys, liver, pancreas, spleen, lungs, bone marrow, and urinary bladder content) for each subject. TACs were generated using Pmod and the absorbed radiation doses were calculated using Olinda 2.2. To compare with the conventional PET/CT, five points were sampled on uEXPLORER's TACs to mimic the result of a short‐axis PET/CT (15 cm axial FOV, consisted of 9 or 10 bed positions). Then the TACs were obtained using the multi‐exponential fitting method, and the residence time and radiation dose were also calculated and compared with uEXPLORER.

Results

The highest absorbed organ doses were the pancreas, thyroid, spleen, heart wall, and kidneys for the male. For the female, the first five highest absorbed organ dose coefficients were the pancreas, heart wall, spleen, lungs, and kidneys. The lowest absorbed dose was found in red marrow both for male and female. The simulated short‐axis PET can fit TACs well for the gradually‐changed uptake organs but typically underestimated for the rapid‐uptake organs during the first‐10 min, resulting in errors in the calculated radiation dose. Conclusion uEXPLORER PET/CT can measure 13 N‐ammonia's TACs simultaneously in all organs of the whole body, which can provide more accurate biodistribution and radiation dose estimation compared with the conventional short‐axis scanners.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyAmmoniaHumansMaleFemaleAdultMiddle AgedAgedTissue DistributionPositron-Emission TomographyTomography, X-Ray ComputedRadiometryRadiopharmaceuticals

Stichwörter der Autor:innen

13N-ammoniabiodistributioninternal radiation dosetotal-body PET/CTuEXPLORER

Substanzen

AmmoniaRadiopharmaceuticals

Autor:innen und Institutionen

  • Department of Nuclear Medicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
  • Central Research Institute, United Imaging Healthcare, Shanghai, People's Republic of China.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • National key research and development program

Zitieren

APA

Yu, X., Sun, H., Xu, L., Han, Y., Wang, C., Li, L., Ng, Y. L., Shi, F., Qiu, J., Huang, G., Zhou, Y., Chen, Y., & Liu, J. (2023). Improved accuracy of the biodistribution and internal radiation dosimetry of 13 N‐ammonia using a total‐body PET/CT scanner. Medical Physics. https://doi.org/10.1002/mp.16450

Vancouver

Yu X, Sun H, Xu L, Han Y, Wang C, Li L, et al. Improved accuracy of the biodistribution and internal radiation dosimetry of 13 N‐ammonia using a total‐body PET/CT scanner. Medical Physics. 2023. doi:10.1002/mp.16450

BibTeX
@article{Yu2023,
  author = {Yu, Xiaofeng and Sun, Hongyan and Xu, Lian and Han, Yuan and Wang, Cheng and Li, Lianghua and Ng, Yee Ling and Shi, Fuxiao and Qiu, Ju and Huang, Gang and Zhou, Yun and Chen, Yumei and Liu, Jianjun},
  title = {Improved accuracy of the biodistribution and internal radiation dosimetry of 13 N‐ammonia using a total‐body PET/CT scanner},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16450}
}
Kostenlos starten →