EUVIMEDOpdag EUVIMED
Crossref

Improved magnetic drug targeting with maximized magnetic forces and limited particle spreading

Rikkert Van Durme iD, Guillaume Crevecoeur iD, Luc Dupré iD, Annelies Coene iD

Medical Physics · 2023

DOI: 10.1002/mp.16180 ↗

At a glance

Journal article in Medical Physics, 2023. Written by Rikkert Van Durme and 3 co-authors. Institution: Department of Electromechanical, Systems and Metal Engineering, Ghent University, Ghent, Belgium. Major MEDLINE topics: Drug Delivery Systems, Nanoparticles. Cited 8 times so far (Crossref); 60 references. Funded by: Fonds Wetenschappelijk Onderzoek.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

In magnetic drug targeting (MDT), micro‐ or nanoparticles are injected into the human body to locally deliver therapeutics. These magnetic particles can be guided from a distance by external magnetic fields and gradients from electromagnets.

Purpose

During the particles' movement through the vascular network, they are affected by magnetic forces, fluid (drag) forces, particle interactions, diffusion, etc. Adequate targeting is hindered when drag forces overcome the magnetic forces and particles present in vessels are carried away from the targeted region. Moreover, the magnetic force directions and diffusion mechanisms can cause particles to scatter, while they should remain together for an effective targeting performance. In this work, these adverse effects are tackled using optimization methods.

Methods

We formulate an optimization problem with respect to the currents in surrounding electromagnets that aims to maximize the magnetic force on a particle along a predefined direction. A boundary on the magnetic force divergence is introduced as a constraint to limit particle spreading. We also consider particles to be moved from an initial to a target location in a finite‐time interval. To this end dynamic optimization is applied.

Results

Simulations for particles in a bifurcated vessel show an increase of particle speed by 20% and a successful movement towards the targeted regions without spreading. For the dynamic optimization, simulation results demonstrate that particle collections are accurately guided with 10 times less scattering and 10 times more particles at the target than without the divergence constraint.

Conclusions

The proposed methods significantly improve the steering and capturing of particles in a region of interest. They are applicable to any magnetic drug targeting configuration with electromagnets.

Subjects

MeSH terms (MEDLINE)

Drug Delivery SystemsNanoparticlesHumansMagnetic FieldsComputer SimulationMagnets

Author keywords

dynamic optimizationmagnetic drug targetingmagnetic nanoparticlesmodelling & optimization

Authors and institutions

  • Department of Electromechanical, Systems and Metal Engineering, Ghent University, Ghent, Belgium.
  • EEDT Decision & Control, core lab Flanders Make, Lommel, Belgium.
  • Cancer Research Institute Ghent, Ghent, Belgium.

ORCID profiles: Rikkert Van Durme, Guillaume Crevecoeur, Luc Dupré, Annelies Coene

Funding

  • Fonds Wetenschappelijk Onderzoek

Cite

APA

Van Durme, R., Crevecoeur, G., Dupré, L., & Coene, A. (2023). Improved magnetic drug targeting with maximized magnetic forces and limited particle spreading. Medical Physics. https://doi.org/10.1002/mp.16180

Vancouver

Van Durme R, Crevecoeur G, Dupré L, Coene A. Improved magnetic drug targeting with maximized magnetic forces and limited particle spreading. Medical Physics. 2023. doi:10.1002/mp.16180

BibTeX
@article{VanDurme2023,
  author = {Van Durme, Rikkert and Crevecoeur, Guillaume and Dupré, Luc and Coene, Annelies},
  title = {Improved magnetic drug targeting with maximized magnetic forces and limited particle spreading},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16180}
}
Start for free →