EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Technical note: In silico benchmarking of the linear energy transfer‐based functionalities for carbon ion beams in a commercial treatment planning system

Mansure Schafasand, Andreas Franz Resch, Erik Traneus, Lars Glimelius, Piero Fossati, Markus Stock, Joanna Gora, Dietmar Georg, Antonio Carlino

Medical Physics · 2023

DOI: 10.1002/mp.16174 ↗

At a glance

Journal article in Medical Physics, 2023. Written by Mansure Schafasand and 8 co-authors. Institution: MedAustron Ion Therapy Center, Wiener Neustadt, Austria. Major MEDLINE topics: Heavy Ion Radiotherapy, Proton Therapy. Cited 9 times so far (Crossref); 34 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

The increasing number of studies dealing with linear energy transfer (LET)‐based evaluation and optimization in the field of carbon ion radiotherapy (CIRT) indicates the rising demand for LET implementation in commercial treatment planning systems (TPS). Benchmarking studies could play a key role in detecting (and thus preventing) computation errors prior implementing such functionalities in a TPS.

Purpose

This in silico study was conducted to benchmark the following two LET‐related functionalities in a commercial TPS against Monte Carlo simulations: (1) dose averaged LET (LET d ) scoring and (2) physical dose filtration based on LET for future LET‐based treatment plan evaluation and optimization studies.

Methods

The LET d scoring and LET‐based dose filtering (in which the deposited dose can be separated into the dose below and above the user specified LET threshold) functionalities for carbon ions in the research version RayStation (RS) 9A‐IonPG TPS (RaySearch Laboratories, Sweden) were benchmarked against GATE/Geant4 simulations. Pristine Bragg peaks (BPs) and cuboid targets, positioned at different depths in a homogeneous water phantom and a setup with heterogeneity were used for this study.

Results

For all setups (homogeneous and heterogeneous), the mean absolute (and relative) LET d difference was less than 1 keV/m (3.5%) in the plateau and target and less than 2 keV/m (8.3%) in the fragmentation tail. The maximum local differences were 4 and 6 keV/m, respectively. The mean absolute (and relative) physical dose differences for both low‐ and high‐LET doses were less than 1 cGy (1.5%) in the plateau, target and tail with a maximum absolute difference of 2 cGy.

Conclusions

No computation error was found in the tested functionalities except for LET d in lateral direction outside the target, showing the limitation of the implemented monochrome model in the tested TPS version.

Subjects

MeSH terms (MEDLINE)

Heavy Ion RadiotherapyProton TherapyLinear Energy TransferCarbonMonte Carlo MethodRadiotherapy Planning, Computer-AssistedRadiotherapy Dosage

Author keywords

GATE/Geant4 Monte Carlo simulationscarbon ion radiotherapylinear energy transfer

Substances

Carbon

Authors and institutions

  • MedAustron Ion Therapy Center, Wiener Neustadt, Austria.
  • Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
  • RaySearch Laboratories AB, Stockholm, Sweden.
  • Department of Oncology, Karl Landsteiner University of Health Sciences, Krems an der Donau, Austria.

Cite

APA

Schafasand, M., Resch, A. F., Traneus, E., Glimelius, L., Fossati, P., Stock, M., Gora, J., Georg, D., & Carlino, A. (2023). Technical note: In silico benchmarking of the linear energy transfer‐based functionalities for carbon ion beams in a commercial treatment planning system. Medical Physics. https://doi.org/10.1002/mp.16174

Vancouver

Schafasand M, Resch AF, Traneus E, Glimelius L, Fossati P, Stock M, et al. Technical note: In silico benchmarking of the linear energy transfer‐based functionalities for carbon ion beams in a commercial treatment planning system. Medical Physics. 2023. doi:10.1002/mp.16174

BibTeX
@article{Schafasand2023,
  author = {Schafasand, Mansure and Resch, Andreas Franz and Traneus, Erik and Glimelius, Lars and Fossati, Piero and Stock, Markus and Gora, Joanna and Georg, Dietmar and Carlino, Antonio},
  title = {Technical note: In silico benchmarking of the linear energy transfer‐based functionalities for carbon ion beams in a commercial treatment planning system},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16174}
}
Start for free →