The innovative 52 g Mn for positron emission tomography (PET) imaging: Production cross section modeling and dosimetric evaluation
Medical Physics · 2023-03 · 50 (3) · 1843-1854
DOI: 10.1002/mp.16130 ↗At a glance
Journal article in Medical Physics, published online on 2022-12-29. Written by Francesca Barbaro and 6 co-authors. Institution: INFN, Sezione di Padova, Padova, Italy. Major MEDLINE topics: Positron-Emission Tomography, Radioisotopes. Cited 5 times so far (Crossref); 50 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Background
Manganese is a paramagnetic element suitable for magnetic resonance imaging (MRI) of neuronal function. However, high concentrations of Mn 2 + can be neurotoxic. 52 g Mn may be a valid alternative as positron emission tomography (PET) imaging agent, to obtain information similar to that delivered by MRI but using trace levels of Mn 2 + , thus reducing its toxicity. Recently, the reaction V(α,x) 52 g Mn has been proposed as a possible alternative to the standard Cr( p ,x) 52 g Mn one, but improvements in the modeling were needed to better compare the two production routes.
Purpose
This work focuses on the development of precise simulations and models to compare the 52 g Mn production from both reactions in terms of amount of activity and radionuclidic purity (RNP), as well as in terms of dose increase (DI) due to the co‐produced radioactive contaminants, versus pure 52 g MnCl 2 .
Methods
The nuclear code Talys has been employed to optimize the V(α,x) 52 g Mn cross section by tuning the parameters of the microscopic level densities. Thick‐target yields have been calculated from the expression of the rates as energy convolution of cross sections and stopping powers, and finally integrating the time evolution of the relevant decay chains. Dosimetric assessments of [Mn]Cl 2 have been accomplished with OLINDA software 2.2.0 using female and male adult phantoms and biodistribution data for 52 g MnCl 2 in normal mice. At the end, the yield of Mn radioisotopes estimated for the two production routes have been combined with the dosimetric results, to assess the DI at different times after the end of the irradiation.
Results
Good agreement was obtained between cross‐section calculations and measurements. The comparison of the two reaction channels suggests that V(α,x) 52 g Mn leads to higher yield and higher purity, resulting in more favorable radiation dosimetry for patients.
Conclusions
Both V(α,x) and Cr( p ,x) production routes provide clinically acceptable 52 g MnCl 2 for PET imaging. However, the V(α,x) 52 g Mn reaction provides a DI systematically lower than the one obtainable with Cr( p ,x) 52 g Mn and a longer time window in which it can be used clinically (RNP ≥ 99%).
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- INFN, Sezione di Padova, Padova, Italy.
- Dipartimento di Fisica dell'Università di Pavia, Pavia, Italy.
- INFN, Sezione di Pavia, Pavia, Italy.
- Dipartimento di Fisica e Astronomia dell'Università di Padova, Padova, Italy.
- Istituto Oncologico Veneto IOV IRCCS, Padova, Italy.
Cite
APA
Barbaro, F., Canton, L., Carante, M. P., Colombi, A., De Nardo, L., Fontana, A., & Meléndez-Alafort, L. (2023). The innovative 52 g Mn for positron emission tomography (PET) imaging: Production cross section modeling and dosimetric evaluation. Medical Physics, 50(3), 1843-1854. https://doi.org/10.1002/mp.16130
Vancouver
Barbaro F, Canton L, Carante MP, Colombi A, De Nardo L, Fontana A, et al. The innovative 52 g Mn for positron emission tomography (PET) imaging: Production cross section modeling and dosimetric evaluation. Medical Physics. 2023;50(3):1843-1854. doi:10.1002/mp.16130
BibTeX
@article{Barbaro2023,
author = {Barbaro, Francesca and Canton, Luciano and Carante, Mario Pietro and Colombi, Alessandro and De Nardo, Laura and Fontana, Andrea and Meléndez-Alafort, Laura},
title = {The innovative 52 g Mn for positron emission tomography (PET) imaging: Production cross section modeling and dosimetric evaluation},
journal = {Medical Physics},
year = {2023},
volume = {50},
number = {3},
pages = {1843--1854},
doi = {10.1002/mp.16130}
}
EUVIMED