EUVIMEDEUVIMED entdecken
Crossref

AuNPs‐HRP microneedle biosensor for ultrasensitive detection of hydrogen peroxide for organ preservation

Jeyaraman S. Narayanan, Gymama Slaughter

MEDICAL DEVICES & SENSORS · 2018

DOI: 10.1002/mds3.10015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift MEDICAL DEVICES & SENSORS, 2018. Verfasst von Jeyaraman S. Narayanan und 1 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: United States Army Medical Command and Materials Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The preservation of tissues and organs for transplantation has garnered considerable attention due to the oxidative stress that arises from the excess of reactive oxygen species produced upon the removal of an organ from its native environment. Herein, gold nanoparticles (AuNPs)‐horseradish peroxidase (HRP) ultrasensitive microneedle biosensor is developed using a simple electrochemical method for the determination of H 2 O 2 . Tungsten microwire was homogenously modified with AuNPs via electrodeposition and 3‐mercaptopropionic acid (MPA) to form self‐assembled monolayers (SAMs) for the immobilization of HRP. The prepared AuNPs‐MPA electrode exhibited high electrocatalytic activity towards the reduction of H 2 O 2 . At an applied potential of −300 mV, the AuNPs‐HRP electrode yielded a linear ranges of 5 nM to 5 µM H 2 O 2 ( R = 0.999) and 1–5 mM H 2 O 2 ( R = 0.985) with a low detection limit of 800 pM and a sensitivity of 490.59 Ma/mM/cm 2 on average as the result of the strong synergistic effect between HRP and AuNPs. Common interfering species such as ascorbic acid, acetaminophen, glucose and uric acid were effectively eliminated. In addition, the fabricated biosensor exhibited high electrocatalytic activity for the determination of H 2 O 2 in real time from rat abdominal wall perfused with histidine–tryptophan–ketoglutarate solution.

Förderung

  • United States Army Medical Command and Materials Research

Zitieren

APA

Narayanan, J. S., & Slaughter, G. (2018). AuNPs‐HRP microneedle biosensor for ultrasensitive detection of hydrogen peroxide for organ preservation. MEDICAL DEVICES & SENSORS. https://doi.org/10.1002/mds3.10015

Vancouver

Narayanan JS, Slaughter G. AuNPs‐HRP microneedle biosensor for ultrasensitive detection of hydrogen peroxide for organ preservation. MEDICAL DEVICES & SENSORS. 2018. doi:10.1002/mds3.10015

BibTeX
@article{Narayanan2018,
  author = {Narayanan, Jeyaraman S. and Slaughter, Gymama},
  title = {AuNPs‐HRP microneedle biosensor for ultrasensitive detection of hydrogen peroxide for organ preservation},
  journal = {MEDICAL DEVICES & SENSORS},
  year = {2018},
  doi = {10.1002/mds3.10015}
}