Comparative Physicochemical Characterization of Electrospun PCL, PLLA, and PLCL Scaffolds and Cell Responses for Tissue Engineering Applications
Macromolecular Bioscience · 2026-01 · 26 (1)
DOI: 10.1002/mabi.202500564 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Macromolecular Bioscience, online erschienen am 16.12.2025. Verfasst von Martyna Polak und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Metals Engineering and Industrial Computer Science, AGH University of Kraków, Kraków, Poland. Hauptthemen laut MEDLINE: Polyesters, Tissue Engineering, Tissue Scaffolds. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 68 Literaturangaben. Gefördert von: Horizon 2020, Narodowe Centrum Nauki.
Abstract (Originalsprache)
In tissue engineering, electrospun scaffolds are valued for their tunable features, which direct cell behavior. Within this study, we electrospun scaffolds from three common polyesters: polycaprolactone (PCL), poly(L‐lactic acid) (PLLA), and poly(lactide‐co‐caprolactone) (PLCL), to identify differences in cell–material interactions. PLLA fibers had the largest average diameter (2.6 ± 0.2 µm), PLCL fiber diameter was intermediate (2.2 ± 0.5 µm), and PCL was the smallest (1.1 ± 0.6 µm). Additionally, X‐ray photoelectron spectroscopy (XPS) revealed distinct surface chemistries that are correlated with streaming potential results at pH 7.4. PLCL fibers showed the most negative zeta potential (−36.4 ± 0.7 mV), followed by PLLA (−28.4 ± 0.8 mV) and PCL (−24.0 ± 0.5 mV). Mechanical testing indicates the highest strength for PLCL mats (5.6 ± 0.9 MPa), then PLLA (3.5 ± 0.3 MPa) and PCL (1.9 ± 0.1 MPa). Cell studies indicated lower initial adhesion of osteoblasts on PLCL (∼53%↓) and PLLA (∼73.6%↓) vs. PCL, likely reflecting PCL scaffold morphology; however, viability at 3 and 7 days was significantly higher on PLCL and PLLA. Microscopy studies confirmed greater filopodia and cell spreading on PLCL and PLLA. Overall, all three are suitable scaffold materials, with PLCL and PLLA supporting cytoskeleton organization and viability better.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Metals Engineering and Industrial Computer Science, AGH University of Kraków, Kraków, Poland.
- Academic Centre for Materials and Nanotechnology, AGH University of Kraków, Kraków, Poland.
ORCID-Profile: Nagalekshmi Uma Thanu Krishnan Neela, Urszula Stachewicz
Förderung
- Horizon 2020
- Narodowe Centrum Nauki
Zitieren
APA
Polak, M., Uma Thanu Krishnan Neela, N., Berniak, K., Knapczyk-Korczak, J., Marzec, M. M., & Stachewicz, U. (2026). Comparative Physicochemical Characterization of Electrospun PCL, PLLA, and PLCL Scaffolds and Cell Responses for Tissue Engineering Applications. Macromolecular Bioscience, 26(1). https://doi.org/10.1002/mabi.202500564
Vancouver
Polak M, Uma Thanu Krishnan Neela N, Berniak K, Knapczyk-Korczak J, Marzec MM, Stachewicz U. Comparative Physicochemical Characterization of Electrospun PCL, PLLA, and PLCL Scaffolds and Cell Responses for Tissue Engineering Applications. Macromolecular Bioscience. 2026;26(1). doi:10.1002/mabi.202500564
BibTeX
@article{Polak2026,
author = {Polak, Martyna and Uma Thanu Krishnan Neela, Nagalekshmi and Berniak, Krzysztof and Knapczyk-Korczak, Joanna and Marzec, Mateusz M and Stachewicz, Urszula},
title = {Comparative Physicochemical Characterization of Electrospun PCL, PLLA, and PLCL Scaffolds and Cell Responses for Tissue Engineering Applications},
journal = {Macromolecular Bioscience},
year = {2026},
volume = {26},
number = {1},
doi = {10.1002/mabi.202500564}
}
EUVIMED