Inter‐ and Intra‐Rater Reliability of 4D ‐ CT Versus Bronchoscopy in Diagnosing and Grading Tracheomalacia
The Laryngoscope · 30.07.2026
DOI: 10.1002/lary.70774 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Laryngoscope, online erschienen am 30.07.2026. Verfasst von Hannah F Case und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, University of Washington, Seattle, Washington, USA. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Objectives
Bronchoscopy and 4D‐CT can be used to diagnose and characterize tracheomalacia. This study aims to assess inter‐ and intra‐rater reliability of rigid bronchoscopy and 4D‐CT imaging in determining tracheomalacia severity.
Methods
De‐identified rigid bronchoscopy videos and 4D‐CT derived airway segmentations were collected for 10 patients with varying degrees of dynamic tracheal collapse, for a total of 20 videos for review. A randomized, multidisciplinary survey was administered to physicians from otolaryngology, pulmonology, general surgery, and radiology at two institutions. Participants rated the severity of collapse for all cases at two time points, 1 month apart. Gwet's AC2 was used to assess inter‐ and intra‐rater reliability, with values ranging from 0 (slight agreement) to 1 (almost perfect agreement).
Results
Nineteen physicians completed the initial ratings (T 1 ), and 12 completed the repeat ratings 1 month later (T 2 ). Inter‐rater agreement for bronchoscopy was substantial at T 1 (AC2 = 0.79, 95% CI: [0.57, 1]) and at T 2 (AC2 = 0.76, 95% CI [0.52, 1]). Similarly, ratings of 4D‐CT segmentations demonstrated substantial agreement initially (T 1 : AC2 = 0.66, 95% CI [0.44, 0.89]) and at T 2 (AC2 = 0.68, 95% CI [0.39, 0.97]). Bronchoscopy (AC2 = 0.91, 95% CI: [0.87, 0.96]) and 4D‐CT (AC2 = 0.84, 95% CI: [0.76, 0.91]) had substantial agreement for intra‐rater reliability.
Conclusion
Endoscopic assessment showed higher inter‐ and intra‐rater reliability than 4D‐CT. Future studies should focus on defining the optimal role of these modalities to establish a standardized severity rating, thereby improving identification of surgical candidates. Level of Evidence 3.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, University of Washington, Seattle, Washington, USA.
- Division of Pediatric Otolaryngology, Seattle Children's Hospital, Seattle, Washington, USA.
- Seattle Children's Research Institute, Seattle Children's Hospital, Seattle, Washington, USA.
- Center for Respiratory Biology and Therapeutics, Seattle Children's Hospital, Seattle, Washington, USA.
- Department of Mechanical Engineering, University of Washington, Seattle, Washington, USA.
- Division of Pediatric Otolaryngology, Children's Mercy Kansas City, Kansas City, Missouri, USA.
ORCID-Profile: Hannah F Case, Shaunak Amin, Tanya Meyer, John P Dahl, Randall A Bly
Förderung
- NIH HHS
- National Institutes of Health
Zitieren
APA
Case, H. F., Amin, S., Wang, X., Barbour, M., Bindschadler, M., Meyer, T., Friedman, S., Aliseda, A., Dahl, J. P., & Bly, R. A. (2026). Inter‐ and Intra‐Rater Reliability of 4D ‐ CT Versus Bronchoscopy in Diagnosing and Grading Tracheomalacia. The Laryngoscope. https://doi.org/10.1002/lary.70774
Vancouver
Case HF, Amin S, Wang X, Barbour M, Bindschadler M, Meyer T, et al. Inter‐ and Intra‐Rater Reliability of 4D ‐ CT Versus Bronchoscopy in Diagnosing and Grading Tracheomalacia. The Laryngoscope. 2026. doi:10.1002/lary.70774
BibTeX
@article{Case2026,
author = {Case, Hannah F and Amin, Shaunak and Wang, Xing and Barbour, Michael and Bindschadler, Michael and Meyer, Tanya and Friedman, Seth and Aliseda, Alberto and Dahl, John P and Bly, Randall A},
title = {Inter‐ and Intra‐Rater Reliability of 4D ‐ CT Versus Bronchoscopy in Diagnosing and Grading Tracheomalacia},
journal = {The Laryngoscope},
year = {2026},
doi = {10.1002/lary.70774}
}
EUVIMED