EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Inter‐ and Intra‐Rater Reliability of 4D ‐ CT Versus Bronchoscopy in Diagnosing and Grading Tracheomalacia

Hannah F Case iD, Shaunak Amin iD, Xing Wang, Michael Barbour, Michael Bindschadler, Tanya Meyer iD, Seth Friedman, Alberto Aliseda, John P Dahl iD, Randall A Bly iD

The Laryngoscope · 30.07.2026

DOI: 10.1002/lary.70774 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Laryngoscope, online erschienen am 30.07.2026. Verfasst von Hannah F Case und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, University of Washington, Seattle, Washington, USA. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Bronchoscopy and 4D‐CT can be used to diagnose and characterize tracheomalacia. This study aims to assess inter‐ and intra‐rater reliability of rigid bronchoscopy and 4D‐CT imaging in determining tracheomalacia severity.

Methods

De‐identified rigid bronchoscopy videos and 4D‐CT derived airway segmentations were collected for 10 patients with varying degrees of dynamic tracheal collapse, for a total of 20 videos for review. A randomized, multidisciplinary survey was administered to physicians from otolaryngology, pulmonology, general surgery, and radiology at two institutions. Participants rated the severity of collapse for all cases at two time points, 1 month apart. Gwet's AC2 was used to assess inter‐ and intra‐rater reliability, with values ranging from 0 (slight agreement) to 1 (almost perfect agreement).

Results

Nineteen physicians completed the initial ratings (T 1 ), and 12 completed the repeat ratings 1 month later (T 2 ). Inter‐rater agreement for bronchoscopy was substantial at T 1 (AC2 = 0.79, 95% CI: [0.57, 1]) and at T 2 (AC2 = 0.76, 95% CI [0.52, 1]). Similarly, ratings of 4D‐CT segmentations demonstrated substantial agreement initially (T 1 : AC2 = 0.66, 95% CI [0.44, 0.89]) and at T 2 (AC2 = 0.68, 95% CI [0.39, 0.97]). Bronchoscopy (AC2 = 0.91, 95% CI: [0.87, 0.96]) and 4D‐CT (AC2 = 0.84, 95% CI: [0.76, 0.91]) had substantial agreement for intra‐rater reliability.

Conclusion

Endoscopic assessment showed higher inter‐ and intra‐rater reliability than 4D‐CT. Future studies should focus on defining the optimal role of these modalities to establish a standardized severity rating, thereby improving identification of surgical candidates. Level of Evidence 3.

Schlagwörter

Stichwörter der Autor:innen

dynamic computed topographypediatric otolaryngologyreliabilitysurveytracheomalacia

Autor:innen und Institutionen

  • Department of Otolaryngology-Head and Neck Surgery, University of Washington, Seattle, Washington, USA.
  • Division of Pediatric Otolaryngology, Seattle Children's Hospital, Seattle, Washington, USA.
  • Seattle Children's Research Institute, Seattle Children's Hospital, Seattle, Washington, USA.
  • Center for Respiratory Biology and Therapeutics, Seattle Children's Hospital, Seattle, Washington, USA.
  • Department of Mechanical Engineering, University of Washington, Seattle, Washington, USA.
  • Division of Pediatric Otolaryngology, Children's Mercy Kansas City, Kansas City, Missouri, USA.

ORCID-Profile: Hannah F Case, Shaunak Amin, Tanya Meyer, John P Dahl, Randall A Bly

Förderung

  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Case, H. F., Amin, S., Wang, X., Barbour, M., Bindschadler, M., Meyer, T., Friedman, S., Aliseda, A., Dahl, J. P., & Bly, R. A. (2026). Inter‐ and Intra‐Rater Reliability of 4D ‐ CT Versus Bronchoscopy in Diagnosing and Grading Tracheomalacia. The Laryngoscope. https://doi.org/10.1002/lary.70774

Vancouver

Case HF, Amin S, Wang X, Barbour M, Bindschadler M, Meyer T, et al. Inter‐ and Intra‐Rater Reliability of 4D ‐ CT Versus Bronchoscopy in Diagnosing and Grading Tracheomalacia. The Laryngoscope. 2026. doi:10.1002/lary.70774

BibTeX
@article{Case2026,
  author = {Case, Hannah F and Amin, Shaunak and Wang, Xing and Barbour, Michael and Bindschadler, Michael and Meyer, Tanya and Friedman, Seth and Aliseda, Alberto and Dahl, John P and Bly, Randall A},
  title = {Inter‐ and Intra‐Rater Reliability of 4D ‐ CT Versus Bronchoscopy in Diagnosing and Grading Tracheomalacia},
  journal = {The Laryngoscope},
  year = {2026},
  doi = {10.1002/lary.70774}
}
Kostenlos starten →