EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Anatomical investigation of safety determining factors for keyhole drilling trajectories for robotic cochlear implant surgery

Saliha Seda Adanır, Piraye Kervancıoğlu, İlhan Bahşi, Mohammad Al Saadi, Paul Van de Heyning, Vedat Topsakal

European Archives of Oto-Rhino-Laryngology · 2025

DOI: 10.1007/s00405-024-09198-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, 2025. Verfasst von Saliha Seda Adanır und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, Faculty of Medicine, Gaziantep University, Gaziantep, Turkey. seda.adnr93@gmail.com. Hauptthemen laut MEDLINE: Cochlear Implantation, Robotic Surgical Procedures, Cochlear Implants, Surgery, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gaziantep University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Cochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea. Image-guided surgery can directly drill with a robotic arm through the mastoid and execute an exact drilling of this precalculated most ideal trajectory. Here, we aim to identify critical anatomical structures determining the safest keyhole drilling trajectory by comparing easy and difficult CI surgeries performed with the HEARO Procedure: a robotic tool for image-guided surgery.

Methods

Cone-beam computed tomography images of patients who underwent robot-assisted cochlear implantation surgery (RACIS) were included. Three of 25 cases had to be converted to conventional surgery because of the current safety mitigations based on anatomical distance. Radiological images in DICOM format were transferred to dedicated software ( OTOPLAN® Cascination GMHB Bern Switzerland ) for analyses. Surgical segmentation and previously planned trajectories were analyzed for these 25 cases by comparing cochlear sizes, facial recess sizes, round window sizes, and trajectory angles. In addition, facial recess angle, and cochlear orientation angles were measured with RadiAnt DICOM Viewer ( Medixant , Pozan , Poland ).

Results

Facial recess size, facial recess angle, and distance between the facial nerve and safe trajectory were smaller in patient who converted from robotic surgery to conventional. A significant positive correlation existed between basal turn angle and in-plane angle (p = 0.001, r = 0.859) . In addition, there was a significant negative correlation between the basal turn length and the last electrode insertion depth degree ( p = 0.007, r = 0.545 ).

Conclusion

In our robotic surgery cases, we demonstrate that the limiting factors of anatomical relationships are constituted by the dimensions of the facial recess and the cochlear orientation. The findings of this study are considered to be a reference for future studies in achieving collision-free trajectory planning in robotic-assisted cochlear implant surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantationRobotic Surgical ProceduresCochlear ImplantsSurgery, Computer-AssistedHumansMaleFemaleCone-Beam Computed TomographyMiddle AgedAdultAgedCochleaChildChild, Preschool

Stichwörter der Autor:innen

Cochlear implantationFacial nerve anatomyFacial recessRobot-assisted cochlear implantation surgerySensorineural hearing lossSurgical anatomy of temporal bone

Autor:innen und Institutionen

  • Department of Anatomy, Faculty of Medicine, Gaziantep University, Gaziantep, Turkey. seda.adnr93@gmail.com.
  • Department of Anatomy, Faculty of Medicine, Gaziantep University, Gaziantep, Turkey.
  • Department of Otorhinolaryngology Head and Neck Surgery, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium.
  • Department of Otorhinolaryngology and Head and Neck Surgery, University Hospital Antwerpen, University of Antwerpen, Antwerp, Belgium.
  • Vrije Universiteit Brussel, Brussels Health Centre, Brussels, Belgium.

Förderung

  • Gaziantep University

Zitieren

APA

Adanır, S. S., Kervancıoğlu, P., Bahşi, İ., Al Saadi, M., Van de Heyning, P., & Topsakal, V. (2025). Anatomical investigation of safety determining factors for keyhole drilling trajectories for robotic cochlear implant surgery. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-024-09198-4

Vancouver

Adanır SS, Kervancıoğlu P, Bahşi İ, Al Saadi M, Van de Heyning P, Topsakal V. Anatomical investigation of safety determining factors for keyhole drilling trajectories for robotic cochlear implant surgery. European Archives of Oto-Rhino-Laryngology. 2025. doi:10.1007/s00405-024-09198-4

BibTeX
@article{Adanr2025,
  author = {Adanır, Saliha Seda and Kervancıoğlu, Piraye and Bahşi, İlhan and Al Saadi, Mohammad and Van de Heyning, Paul and Topsakal, Vedat},
  title = {Anatomical investigation of safety determining factors for keyhole drilling trajectories for robotic cochlear implant surgery},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2025},
  doi = {10.1007/s00405-024-09198-4}
}
Kostenlos starten →