EUVIMEDEUVIMED entdecken
Crossref

Anterior and posterior parts of diaphragm: A search for the best recording sites and the relevant normative data with surface electrodes

Volkan Tasdemir iD, Nermin Gorkem Sirin iD, Ali Emre Oge iD, Elif Kocasoy Orhan iD

Ideggyógyászati szemle · 2026

DOI: 10.18071/isz.79.0035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ideggyógyászati szemle, 2026. Verfasst von Volkan Tasdemir und 3 weiteren Autor:innen. Beteiligte Einrichtung: Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Türkiye. Hauptthemen laut MEDLINE: Diaphragm, Phrenic Nerve.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and purpose Phrenic nerve conduction studies, including comprehensive recording of compound muscle action potentials (CMAP) from all regions of the dia­ phragm, can be useful in both neurolo­gical conditions affecting the phrenic nerve or diaphragm and non-neurological conditions such as COPD and GERD, and may have potential diagnostic value. It was aimed (a) to determine the most convenient stimulation and recording sites for phrenic nerve conduction studies (NCS), (b) to record CMAPs reflecting the activity of the posterior part of the diaphragm with surface recording electrodes, (c) to define normative values for these studies.

Methods

Sixty-three healthy subjects were included in the study and CMAPs were recorded simultaneously with two anterior and two posterior electrode derivations while stimulating the phrenic nerve behind the sternocleidomastoid muscle.

Results

Among the four different electrode placements, the recording electrode pairs providing the highest amplitude CMAPs were those placed 5 cm above the xiphoid process (active) and 16 cm laterally on the costal margin (reference). With this placement method, the upper limit of CMAP latency was 7.70 ms, the lower limit of base-topeak amplitude was 0.30 mV and the lower limit of peak-to-peak amplitude was 0.45 mV. Diaphragmatic CMAPs have been obtained from the majority of volunteers with surface electrodes placed in the posterior regions of the diaphragm, albeit with lower amplitude. Age is the only independent factor affecting the CMAP latency in this study.

Conclusion

Normative values with the best recording sites for phrenic NCSs were determined. The posterior aspect of the diaphragm could be recorded with surface electrodes despite the lower amplitude and reliability compared to the anterior part.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DiaphragmPhrenic NerveHumansMaleFemaleNerve Conduction StudiesAdultElectrodesMiddle AgedReference ValuesAction PotentialsYoung AdultElectromyographyAged

Stichwörter der Autor:innen

crural partdiaphragmhealthy subjectsmotor nerve conduction studynormative valuesphrenic nerveposterior part of diaphragm

Autor:innen und Institutionen

  • Departments of Neurology and Clinical Neurophysiology, Istanbul Faculty of Medicine, Istanbul University, Türkiye.

ORCID-Profile: Volkan Tasdemir, Nermin Gorkem Sirin, Ali Emre Oge, Elif Kocasoy Orhan

Zitieren

APA

Tasdemir, V., Sirin, N. G., Oge, A. E., & Orhan, E. K. (2026). Anterior and posterior parts of diaphragm: A search for the best recording sites and the relevant normative data with surface electrodes. Ideggyógyászati szemle. https://doi.org/10.18071/isz.79.0035

Vancouver

Tasdemir V, Sirin NG, Oge AE, Orhan EK. Anterior and posterior parts of diaphragm: A search for the best recording sites and the relevant normative data with surface electrodes. Ideggyógyászati szemle. 2026. doi:10.18071/isz.79.0035

BibTeX
@article{Tasdemir2026,
  author = {Tasdemir, Volkan and Sirin, Nermin Gorkem and Oge, Ali Emre and Orhan, Elif Kocasoy},
  title = {Anterior and posterior parts of diaphragm: A search for the best recording sites and the relevant normative data with surface electrodes},
  journal = {Ideggyógyászati szemle},
  year = {2026},
  doi = {10.18071/isz.79.0035}
}
Kostenlos starten →