EUVIMEDEUVIMED entdecken
Crossref

Inter‐rater and Intra‐rater Reliability of Glottal Image Capture: A Mobile Application to Quantify Vocal Fold Bowing

Mohamed Aboueisha iD, Zaroug Jaleel, Hans C Baertsch iD, Cara Sauder, Albert L Merati, Michael M Johns, Neel K Bhatt iD

The Laryngoscope · 2025

DOI: 10.1002/lary.31942 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Laryngoscope, 2025. Verfasst von Mohamed Aboueisha und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Laryngology, Department of Otolaryngology - Head and Neck Surgery, University of Washington School of Medicine, Seattle, Washington, U.S.…. Hauptthemen laut MEDLINE: Vocal Cords, Mobile Applications, Glottis, Stroboscopy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Age‐related vocal atrophy (ARVA) causes vocal fold bowing, impacting communication and quality of life. The assessment of vocal fold bowing is largely subjective. Glottal Image Capture (GlottIC) is a new mobile application that helps quantify vocal fold bowing. We aim through this study to assess its reliability, compare it to manual calculation method, and compare differences between visual‐perceptual bowing severity ratings.

Methods

Ten raters independently quantified Bowing Index (BI) using GlottIC from 10 videostroboscopic images among individuals with ARVA. There was 100% duplication of images to facilitate intra‐rater reliability analyses using Pearson's correlation. Inter‐rater reliability was quantified using Intraclass Correlation Coefficient (ICC) for experienced and novice raters. The correlation between manual calculations using ImageJ and GlottIC was analyzed.

Results

The intra‐rater reliability for total BI was strong ( r = 0.822, p < 0.001). The inter‐rater reliability for BI, calculated using ICC, was (ICC = 0.720; 95% CI: 0.579–0.852), indicating good consistency among the raters. Experts had higher ICC (ICC = 0.808; 95% CI: 0.678–0.906) compared to novice raters (ICC = 0.651; 95% CI: 0.468–0.816). There was a positive correlation between GlottIC and manual BI ( r = 0.811, p < 0.001). As the BI increased, the bowing severity, based on visual‐perceptual ratings, also increased ( p < 0.001).

Conclusion

GlottIC is a reliable mobile application that can quantify vocal fold bowing in patients with ARVA with high intra‐ and inter‐rater reliability. GlottIC BI measurments are highly correlated with manual BI and visual‐perceptual ratings of bowing severity. Further improvements in reliability may be achieved with more robust rater training and automated technologies. Level of Evidence 3 Laryngoscope , 135:1732–1736, 2025

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vocal CordsMobile ApplicationsGlottisStroboscopyLaryngeal DiseasesHumansReproducibility of ResultsObserver VariationMaleFemaleMiddle AgedAtrophyAdultAgedSeverity of Illness IndexVideo Recording

Stichwörter der Autor:innen

Bowing Indexaging larynxquantification of vocal fold measuresvocal fold atrophy

Autor:innen und Institutionen

  • Division of Laryngology, Department of Otolaryngology - Head and Neck Surgery, University of Washington School of Medicine, Seattle, Washington, U.S.A.
  • Department of Otolaryngology - Head and Neck Surgery, Faculty of Medicine Suez Canal University, Ismailia, Egypt.
  • Department of Otolaryngology - Head and Neck Surgery, University of Minnesota, Minneapolis, Minnesota, U.S.A.
  • Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington, U.S.A.
  • Caruso Department of Otolaryngology - Head and Neck Surgery, Keck School of Medicine, University of Southern California, Los Angeles, California, U.S.A.

ORCID-Profile: Mohamed Aboueisha, Hans C Baertsch, Neel K Bhatt

Zitieren

APA

Aboueisha, M., Jaleel, Z., Baertsch, H. C., Sauder, C., Merati, A. L., Johns, M. M., & Bhatt, N. K. (2025). Inter‐rater and Intra‐rater Reliability of Glottal Image Capture: A Mobile Application to Quantify Vocal Fold Bowing. The Laryngoscope. https://doi.org/10.1002/lary.31942

Vancouver

Aboueisha M, Jaleel Z, Baertsch HC, Sauder C, Merati AL, Johns MM, et al. Inter‐rater and Intra‐rater Reliability of Glottal Image Capture: A Mobile Application to Quantify Vocal Fold Bowing. The Laryngoscope. 2025. doi:10.1002/lary.31942

BibTeX
@article{Aboueisha2025,
  author = {Aboueisha, Mohamed and Jaleel, Zaroug and Baertsch, Hans C and Sauder, Cara and Merati, Albert L and Johns, Michael M and Bhatt, Neel K},
  title = {Inter‐rater and Intra‐rater Reliability of Glottal Image Capture: A Mobile Application to Quantify Vocal Fold Bowing},
  journal = {The Laryngoscope},
  year = {2025},
  doi = {10.1002/lary.31942}
}
Kostenlos starten →