Repeatability and intra and interrater reproducibility of the DIPA-S eHealth© capture and analysis system for clinical assessment of scoliosis
European Spine Journal · 2024
DOI: 10.1007/s00586-024-08410-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Spine Journal, 2024. Verfasst von Isis Juliene Rodrigues Leite Navarro und 3 weiteren Autor:innen. Beteiligte Einrichtung: Universidade Federal do Rio Grande do Sul - Grupo Biomec, Rua Felizardo, 750, bairro Jardim Botânico, Porto Alegre, Rio Grande do Sul, Brasil. isisjl…. Hauptthemen laut MEDLINE: Scoliosis, Telemedicine. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Themen: Digitalisierung in der Pflege
Abstract (Originalsprache)
PURPOSE: To assess the repeatability, intra and interrater reproducibility of the DIPA-S eHealth© system for capturing and measuring clinical variables of scoliosis, including frontal trunk imbalance (FTI), sagittal trunk imbalance (STI), and angle of trunk rotation (ATR). METHODS: Patients were photographed using the DIPA-S eHealth Capture© mobile application by family members, physiotherapists, or surgeons. Three photos were taken in each position: standing in the frontal and sagittal planes and in the axial plane in forward bending position of the trunk. The photos were analyzed by three independent evaluators using the DIPA-S eHealth Analysis© software. For repeatability, each photo was analyzed twice consecutively by the three evaluators. For intrarater reproducibility, only one evaluator reanalyzed the first photo from each plane with a 5-day interval. For interrater reproducibility, the three evaluators analyzed the first photo from each plane. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were used (p < 0.05). RESULTS: The sample comprised 262 images (n = 30). Repeatability was excellent for all three evaluators in all three planes (ICC 0.94 to 1.00). Intrarater reproducibility was excellent in all three planes (ICC 0.88 to 0.99). Interrater analysis was excellent for the frontal and axial planes (ICC 0.98 and 0.93), respectively. However, it was weak in the sagittal plane ICC 0.32. The SEM ranged from 0.02 to 17.6 and MDC from 0.03 to 34.6. CONCLUSION: The DIPA-S eHealth© Capture and Analysis system demonstrates reproducibility for use in the clinical assessment of scoliosis through teleconsultations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Universidade Federal do Rio Grande do Sul - Grupo Biomec, Rua Felizardo, 750, bairro Jardim Botânico, Porto Alegre, Rio Grande do Sul, Brasil. isisjlnavarro@gmail.com.
- Universidade Federal do Rio Grande do Sul - Grupo Biomec, Rua Felizardo, 750, bairro Jardim Botânico, Porto Alegre, Rio Grande do Sul, Brasil.
Zitieren
APA
Navarro, I. J. R. L., Silva, M. G., Dos Santos, I. C. P., & Candotti, C. T. (2024). Repeatability and intra and interrater reproducibility of the DIPA-S eHealth© capture and analysis system for clinical assessment of scoliosis. European Spine Journal. https://doi.org/10.1007/s00586-024-08410-7
Vancouver
Navarro IJRL, Silva MG, Dos Santos ICP, Candotti CT. Repeatability and intra and interrater reproducibility of the DIPA-S eHealth© capture and analysis system for clinical assessment of scoliosis. European Spine Journal. 2024. doi:10.1007/s00586-024-08410-7
BibTeX
@article{Navarro2024,
author = {Navarro, Isis Juliene Rodrigues Leite and Silva, Marcelle Guimarães and Dos Santos, Ingrid Cláudia Pereira and Candotti, Cláudia Tarragô},
title = {Repeatability and intra and interrater reproducibility of the DIPA-S eHealth© capture and analysis system for clinical assessment of scoliosis},
journal = {European Spine Journal},
year = {2024},
doi = {10.1007/s00586-024-08410-7}
}
EUVIMED