Frequency‐to‐Place Mismatch Impacts Cochlear Implant Quality of Life, But Not Speech Recognition
The Laryngoscope · 2024
DOI: 10.1002/lary.31264 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Laryngoscope, 2024. Verfasst von Joshua J Sturm und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, U.S.A. Hauptthemen laut MEDLINE: Quality of Life, Cochlear Implants, Speech Perception, Cochlear Implantation. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDCD NIH HHS, National Institute on Deafness and Other Communication Disorders.
Abstract (Originalsprache)
Objective
To retrospectively compare frequency‐place mismatch among adult cochlear implant (CI) recipients with lateral wall (LW) and perimodiolar/Mid Scala (PM/MS) arrays, and to quantify the impact of these factors on early post‐activation (3 months) speech recognition abilities and CI‐specific quality of life. Method s One hundred and twenty‐six adult participants were separated into two groups: (1) 83 participants who underwent CI with a PM/MS array and 43 patients who underwent CI with a LW array. All participants completed the Cochlear Implant Quality of Life Profile (CIQOL‐35 Profile) instrument. Angular insertion depth and semitone mismatch, which contribute to frequency‐place mismatch, were assessed using post‐operative CT scans. Word and speech recognition in quiet were determined using the Consonant‐Nucleus‐Consonant (CNC) and the AzBio tests, respectively ( n = 82 patients).
Results
LW arrays were more deeply inserted and exhibited less semitone mismatch compared to PM/MS arrays. No significant relationship was found between semitone mismatch and early post‐operative speech perception scores for either PM/MS or LW arrays. However, greater degrees of semitone mismatch were associated with lower CIQOL‐35 profile scores for PM/MS arrays. Conclusions and Relevance The results of this study indicate that both the degree of frequency‐place mismatch, and its impact on CI‐specific quality of life, vary by CI array design. Level of Evidence 4 Laryngoscope , 134:2898–2905, 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, U.S.A.
- Department of Otolaryngology-Head and Neck Surgery, Penn State College of Medicine, Hershey, Pennsylvania, U.S.A.
ORCID-Profile: Joshua J Sturm, Cheng Ma, Theodore R McRackan, Kara C Schvartz-Leyzac
Förderung
- NIDCD NIH HHS
- National Institute on Deafness and Other Communication Disorders
Zitieren
APA
Sturm, J. J., Ma, C., McRackan, T. R., & Schvartz-Leyzac, K. C. (2024). Frequency‐to‐Place Mismatch Impacts Cochlear Implant Quality of Life, But Not Speech Recognition. The Laryngoscope. https://doi.org/10.1002/lary.31264
Vancouver
Sturm JJ, Ma C, McRackan TR, Schvartz-Leyzac KC. Frequency‐to‐Place Mismatch Impacts Cochlear Implant Quality of Life, But Not Speech Recognition. The Laryngoscope. 2024. doi:10.1002/lary.31264
BibTeX
@article{Sturm2024,
author = {Sturm, Joshua J and Ma, Cheng and McRackan, Theodore R and Schvartz-Leyzac, Kara C},
title = {Frequency‐to‐Place Mismatch Impacts Cochlear Implant Quality of Life, But Not Speech Recognition},
journal = {The Laryngoscope},
year = {2024},
doi = {10.1002/lary.31264}
}
EUVIMED