Cochlear Implant Qualification in Noise Versus Quiet: Do Patients Demonstrate Similar Postoperative Benefits?
Otolaryngology–Head and Neck Surgery · 2024
DOI: 10.1002/ohn.677 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Otolaryngology–Head and Neck Surgery, 2024. Verfasst von Natalie Schauwecker und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: Noise, Cochlear Implants, Speech Perception, Quality of Life. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: NIDCD NIH HHS, NCATS NIH HHS.
Abstract (Originalsprache)
Objective
To assess patient factors, audiometric performance, and patient‐reported outcomes in cochlear implant (CI) patients who would not have qualified with in‐quiet testing alone. Study Design Retrospective chart review.
Setting
Tertiary referral center.
Methods
Adult CI recipients implanted between 2012 and 2022 were identified. Patients with preoperative AzBio Quiet > 60% in the implanted ear, requiring multitalker babble to qualify, comprised the in‐noise qualifying (NQ) group. NQ postoperative performance was compared with the in‐quiet qualifying (QQ) group using CNC, AzBio Quiet, and AzBio +5 dB signal‐to‐noise ratio. Speech, Spatial and Qualities of Hearing Scale (SSQ), Cochlear Implant Quality of Life scale (CIQOL‐10), and daily device usage were also compared between the groups.
Results
The QQ group (n = 771) and NQ group (n = 67) were similar in age and hearing loss duration. NQ had higher average preoperative and postoperative speech recognition scores. A larger proportion of QQ saw significant improvement in CNC and AzBio Quiet scores in the CI‐only listening condition (eg, CI‐only AzBio Quiet: 88% QQ vs 51% NQ, P < .001). Improvement in CI‐only AzBio +5 dB and in all open set testing in the best‐aided binaural listening condition was similar between groups (eg, Binaural AzBio Quiet 73% QQ vs 59% NQ, P = .345). Postoperative SSQ ratings, CIQOL scores, and device usage were also equivalent between both groups.
Conclusion
Patients who require in‐noise testing to meet CI candidacy demonstrate similar improvements in best‐aided speech perception and patient‐reported outcomes as in‐QQ, supporting the use of in‐noise testing to determine CI qualification for borderline CI candidates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Förderung
- NIDCD NIH HHS
- NCATS NIH HHS
Zitieren
APA
Schauwecker, N., Patro, A., Holder, J. T., Bennett, M. L., Perkins, E., & Moberly, A. C. (2024). Cochlear Implant Qualification in Noise Versus Quiet: Do Patients Demonstrate Similar Postoperative Benefits?. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.677
Vancouver
Schauwecker N, Patro A, Holder JT, Bennett ML, Perkins E, Moberly AC. Cochlear Implant Qualification in Noise Versus Quiet: Do Patients Demonstrate Similar Postoperative Benefits?. Otolaryngology–Head and Neck Surgery. 2024. doi:10.1002/ohn.677
BibTeX
@article{Schauwecker2024,
author = {Schauwecker, Natalie and Patro, Ankita and Holder, Jourdan T and Bennett, Marc L and Perkins, Elizabeth and Moberly, Aaron C},
title = {Cochlear Implant Qualification in Noise Versus Quiet: Do Patients Demonstrate Similar Postoperative Benefits?},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2024},
doi = {10.1002/ohn.677}
}
EUVIMED