Comparison of computed tomography‐based tibial torsion measurement techniques reveals significant technique‐dependent differences
Knee Surgery, Sports Traumatology, Arthroscopy · 09.11.2026
DOI: 10.1002/ksa.70672 ↗Kurz gefasst
Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 09.11.2026. Verfasst von Marcis Benefelds und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Trauma Surgery, Medical University of Innsbruck, Innsbruck, Austria. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
Purpose
To compare commonly used computed tomography (CT)‐based tibial torsion measurement discrepancies and evaluate their intra‐ and interobserver agreement, as measurement discrepancies between techniques have not been systematically assessed.
Methods
CT scans from 20 adult patients were retrospectively analysed. Tibial torsion was calculated using two proximal reference axes (posterior tibial plateau tangent and tibial tuberosity axis) and four distal axes (transmalleolar, ankle joint, Jend and Waidelich). Three observers performed all measurements independently and repeated them after 8–12 weeks. Differences among techniques were assessed using repeated‐measures analysis of variance with Bonferroni correction. Reliability was evaluated using intraclass correlation coefficients (ICCs).
Results
All measurement techniques differed significantly ( p < 0.05). Mean tibial torsion was 34.1° (standard deviation [SD] 8.6°) for the transmalleolar axis, 31.2° (SD 8.8°) for the ankle joint axis, 44.2° (SD 9.8°) for the Jend axis and 34.9° (SD 9.0°) for the Waidelich axis. Segmental values revealed a mean supratuberositary torsion of 26° (SD 6.7°) and a mean infratuberositary torsion of 7.9° (SD 8.8°) for the transmalleolar axis, 5.1° (SD 8.9°) for the ankle joint axis, 18.1° (SD 10.4°) for the Jend axis and 8.8° (SD 9.1°) for the Waidelich axis. All techniques showed excellent intra‐ and interobserver reliability (ICC > 0.89).
Conclusion
Tibial torsion values depended strongly on the measurement technique used. Technique‐specific normative values are essential, and radiology reports should explicitly identify the technique applied. Clinicians must account for these systematic differences when interpreting torsion values and planning derotational osteotomies. Level of Evidence Level III, retrospective comparative study.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Trauma Surgery, Medical University of Innsbruck, Innsbruck, Austria.
- Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
- Sportklinik Arlberg GmbH, St. Anton am Arlberg, Austria.
ORCID-Profile: Marcis Benefelds
Zitieren
APA
Benefelds, M., Juen, U., Kaiser, P., Lindtner, R., Kummann, M., & Mayr, R. (2026). Comparison of computed tomography‐based tibial torsion measurement techniques reveals significant technique‐dependent differences. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.70672
Vancouver
Benefelds M, Juen U, Kaiser P, Lindtner R, Kummann M, Mayr R. Comparison of computed tomography‐based tibial torsion measurement techniques reveals significant technique‐dependent differences. Knee Surgery, Sports Traumatology, Arthroscopy. 2026. doi:10.1002/ksa.70672
BibTeX
@article{Benefelds2026,
author = {Benefelds, Marcis and Juen, Ulrich and Kaiser, Peter and Lindtner, Richard and Kummann, Moritz and Mayr, Raul},
title = {Comparison of computed tomography‐based tibial torsion measurement techniques reveals significant technique‐dependent differences},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2026},
doi = {10.1002/ksa.70672}
}
EUVIMED