No significant change in tibial torsion despite hinge fracture after high tibial osteotomy using patient‐specific instruments
Journal of Experimental Orthopaedics · 2026-10 · 13 (4)
DOI: 10.1002/jeo2.70960 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Experimental Orthopaedics, online erschienen am 26.10.2026. Verfasst von Luca Maddaloni und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics Balgrist University Hospital, University of Zurich Zurich Switzerland. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Medial open wedge high tibial osteotomy (MOW‐HTO) is an established treatment option for medial knee osteoarthritis or overload. However, using the conventional technique, unintended postoperative changes of the tibial torsion angle (TTA) were observed, potentially leading to secondary patellofemoral or gait disorders. This study aimed to investigate postoperative TTA changes after MOW‐HTO performed with patient‐specific instruments (PSI), with particular attention to the influence of hinge fracture.
Methods
All patients who underwent MOW‐HTO from October 2014 to December 2024 were included retrospectively. Pre‐ and postoperative radiographs and computed tomography (CT) were used to screen for HF and changes in TTA, posterior tibial slope (PTS), hip‐knee‐ankle angle (HKA) and opening wedge distance (OWD) were measured.
Results
One hundred and eighteen knees were included, in which 52 HF (44.1%) were detected and classified according to Takeuchi (type I: n = 40, type II = 11, type III = 1). Overall, TTA showed no significant change from pre‐ to postoperative (25.1° ± 8.5°, 25.0° ± 8.6°, p = 0.727). HF group showed no significant change in TTA (24.3° ± 8.6°, 24.2° ± 9.0°, p = 0.803). Furthermore, HF group has significantly larger OWD values than patients in the no HF group (no HF group: 7.4 mm ± 2.1 mm, HF group: 9.2 mm ± 2.9 mm, p < 0.001). PTS changed significantly in the HF group (no HF group: 0.3° ± 1.9°, HF group: 2.0° ± 2.6°, p < 0.001).
Conclusion
No significant change in TTA was observed in MOW‐HTO performed with a PSI system consisting of an osteotomy guide followed by a reduction guide. TTA also remained stable in cases with a hinge fracture. Level of Evidence Level III.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics Balgrist University Hospital, University of Zurich Zurich Switzerland.
ORCID-Profile: Luca Maddaloni
Zitieren
APA
Maddaloni, L., Jud, L., Fischer, L., Vlachopoulos, L., & Fucentese, S. F. (2026). No significant change in tibial torsion despite hinge fracture after high tibial osteotomy using patient‐specific instruments. Journal of Experimental Orthopaedics, 13(4). https://doi.org/10.1002/jeo2.70960
Vancouver
Maddaloni L, Jud L, Fischer L, Vlachopoulos L, Fucentese SF. No significant change in tibial torsion despite hinge fracture after high tibial osteotomy using patient‐specific instruments. Journal of Experimental Orthopaedics. 2026;13(4). doi:10.1002/jeo2.70960
BibTeX
@article{Maddaloni2026,
author = {Maddaloni, Luca and Jud, Lukas and Fischer, Lukas and Vlachopoulos, Lazaros and Fucentese, Sandro F},
title = {No significant change in tibial torsion despite hinge fracture after high tibial osteotomy using patient‐specific instruments},
journal = {Journal of Experimental Orthopaedics},
year = {2026},
volume = {13},
number = {4},
doi = {10.1002/jeo2.70960}
}