EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Real-world accuracy of robotic-assisted total knee arthroplasty and its impact on expedited recovery

Wai Kit Wong, Azliana Abu Bakar Sajak, Hwa Sen Chua

Journal of Robotic Surgery · 2024

DOI: 10.1007/s11701-024-02059-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Robotic Surgery, 2024. Verfasst von Wai Kit Wong und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Hospital Ampang, Jalan Mewah Utara, Taman Pandan Mewah, 68000, Ampang, Selangor, Malaysia. wkwong.dr@gma…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite total knee arthroplasty (TKA) being the gold standard for end-stage knee osteoarthritis, 20% of patients remain dissatisfied. Robotic-assisted arthroplasty promises unparalleled control of the accuracy of bone cuts, implant positioning, control of gap balance, and resultant hip–knee–ankle (HKA) axis. Patients underwent clinical and radiological assessments, including knee CT scans and patient-reported outcome measures (PROMs), preoperatively. Follow-up assessments were conducted at 2 weeks, 6 weeks, and 3 months post-operatively, with imaging repeated at 6 weeks. A total of 155 patients underwent robotic-assisted TKA and have completed 3 months of follow-up. Mean pre-operative HKA axis was 7.39 ± 5.52 degrees varus, improving to 1.34 ± 2.22 degrees varus post-operatively. Restoration of HKA axis was 0.76 ± 1.9 degrees from intra-operative planning ( p < 0.0005). Implant placement accuracy in the coronal plane was 0.08 ± 1.36 degrees ( p = 0.458) for the femoral component and 0.71 ± 1.3 degrees ( p < 0.0005) for the tibial component. Rotational alignment mean deviation was 0.39 ± 1.49 degrees ( p = 0.001). Most patients (98.1%) had ≤ 2 mm difference in extension–flexion gaps. PROM scores showed improvement and exceeded pre-operative scores by 6 weeks post-surgery. Robotic-assisted knee arthroplasty provides precise control over traditionally subjective factors, demonstrating excellent early post-operative outcomes. Level of evidence Prospective observational study—II.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresHumansFemaleMaleAgedMiddle AgedOsteoarthritis, KneePatient Reported Outcome MeasuresAged, 80 and overTreatment OutcomeRecovery of FunctionKnee JointProspective Studies

Stichwörter der Autor:innen

Functional alignmentMAKORobotic surgeryRobotic total knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Hospital Ampang, Jalan Mewah Utara, Taman Pandan Mewah, 68000, Ampang, Selangor, Malaysia. wkwong.dr@gmail.com.
  • Clinical Research Centre, Sunway Medical Centre, Bandar Sunway, 47500, Subang Jaya, Selangor, Malaysia.
  • Orthopaedic Centre of Excellence, Sunway Medical Centre, Bandar Sunway, 47500, Subang Jaya, Selangor, Malaysia.

Zitieren

APA

Wong, W. K., Abu Bakar Sajak, A., & Chua, H. S. (2024). Real-world accuracy of robotic-assisted total knee arthroplasty and its impact on expedited recovery. Journal of Robotic Surgery. https://doi.org/10.1007/s11701-024-02059-6

Vancouver

Wong WK, Abu Bakar Sajak A, Chua HS. Real-world accuracy of robotic-assisted total knee arthroplasty and its impact on expedited recovery. Journal of Robotic Surgery. 2024. doi:10.1007/s11701-024-02059-6

BibTeX
@article{Wong2024,
  author = {Wong, Wai Kit and Abu Bakar Sajak, Azliana and Chua, Hwa Sen},
  title = {Real-world accuracy of robotic-assisted total knee arthroplasty and its impact on expedited recovery},
  journal = {Journal of Robotic Surgery},
  year = {2024},
  doi = {10.1007/s11701-024-02059-6}
}
Kostenlos starten →