EUVIMEDEUVIMED entdecken
Vergleichsstudie

Better functional scores at 5 years following TKA with unrestricted kinematic alignment using medial‐pivot versus ultracongruent implants

Emmanuel Marchetti iD, Lison Bulle, Antoine Combes, ReSurg, Loïc Laurendon, Roger Badet

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-11 · 34 (11) · 4103-4112

DOI: 10.1002/ksa.70382 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 22.04.2026. Verfasst von Emmanuel Marchetti und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centre OsteoArticulaire Fleming, Bourgoin-Jallieu, France. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Osteoarthritis, Knee, Knee Joint. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Medacta.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose was to compare patient‐reported outcome measures (PROMs) at 5 years following total knee arthroplasty (TKA) using unrestricted kinematic alignment with ultracongruent (UC) versus cruciate‐sacrificing medial pivot (CS‐MP) and versus cruciate‐retaining medial pivot (CR‐MP) designs.

Methods

This was a retrospective analysis of a consecutive cohort of 140 TKAs with UC ( n = 44), CS‐MP ( n = 44) and CR‐MP ( n = 52). Of the initial cohort, three died, leaving a final cohort of 137 (UC, n = 43; CS‐MP, n = 44; CR‐MP, n = 50). Patients completed pre‐ and post‐operative questionnaires of the Knee Society Score (KSS 2011) Symptoms, Satisfaction, Expectations and Function components, the Kujala score and the Forgotten Joint Score (FJS). Multivariable analyses were performed to assess the association of implant type (CR‐MP, CS‐MP and UC) with postoperative Kujala score and FJS, adjusting for patient characteristics (age, body mass index [BMI], sex, preoperative phenotype, expectations and Wiberg classification).

Results

Postoperative Kujala scores were significantly better for CR‐MP and CS‐MP (80.1 ± 9.8 and 82.1 ± 9.8) compared to UC (73.3 ± 14.4; p = 0.007 and p < 0.001). After adjusting for patient factors, multivariable analysis revealed a statistically significant negative association between postoperative Kujala scores and UC ( β = −6.270; p = 0.011). Postoperative FJS was significantly better for CS‐MP compared to UC (88.9 ± 11.5 vs. 74.9 ± 23.4; p = 0.024). After adjusting for age and sex, multivariable analysis did not reveal a statistically significant association between postoperative FJS and UC ( β = −6.58; p = n.s.).

Conclusion

At 5‐year follow‐up, TKA using unrestricted kinematic alignment with MP designs achieved superior functional outcomes compared to UC designs, but no significant difference between CS‐MP and CR‐MP designs. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeKnee JointHumansRetrospective StudiesFemaleMaleAgedProsthesis DesignBiomechanical PhenomenaPatient Reported Outcome MeasuresRecovery of FunctionMiddle AgedPatient Satisfaction

Stichwörter der Autor:innen

PROMsmedial pivottotal knee arthroplastyultracongruentunrestricted kinematic alignment

Autor:innen und Institutionen

  • Centre OsteoArticulaire Fleming, Bourgoin-Jallieu, France.
  • Medipole de Lyon, Lyon, France.
  • Clinique Saint Vincent de Paul, Lyon, France.
  • ReSurg SA, Nyon, Switzerland.
  • Clinique Saint Charles, Lyon, France.

ORCID-Profile: Emmanuel Marchetti

Förderung

  • Medacta

Zitieren

APA

Marchetti, E., Bulle, L., Combes, A., ReSurg, Laurendon, L., & Badet, R. (2026). Better functional scores at 5 years following TKA with unrestricted kinematic alignment using medial‐pivot versus ultracongruent implants. Knee Surgery, Sports Traumatology, Arthroscopy, 34(11), 4103-4112. https://doi.org/10.1002/ksa.70382

Vancouver

Marchetti E, Bulle L, Combes A, ReSurg, Laurendon L, Badet R. Better functional scores at 5 years following TKA with unrestricted kinematic alignment using medial‐pivot versus ultracongruent implants. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(11):4103-4112. doi:10.1002/ksa.70382

BibTeX
@article{Marchetti2026,
  author = {Marchetti, Emmanuel and Bulle, Lison and Combes, Antoine and ReSurg, ReSurg and Laurendon, Loïc and Badet, Roger},
  title = {Better functional scores at 5 years following TKA with unrestricted kinematic alignment using medial‐pivot versus ultracongruent implants},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {11},
  pages = {4103--4112},
  doi = {10.1002/ksa.70382}
}
Kostenlos starten →