EUVIMEDEUVIMED entdecken
Crossref

Static native tibial alignment in total knee arthroplasty optimises whole‐body gait kinematics

Zhijun Li iD, Philip Winnock de Grave, Tamaya Van Criekinge, Thomas Luyckx, Kurt Claeys iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-11 · 34 (11) · 4049-4062

DOI: 10.1002/ksa.70356 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 24.02.2026. Verfasst von Zhijun Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Sciences, KU Leuven, Brugge, Belgium. Hauptthemen laut MEDLINE: Gait, Arthroplasty, Replacement, Knee, Tibia, Osteoarthritis, Knee. Die Arbeit nennt 51 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the impact of static native tibial alignment in total knee arthroplasty (TKA) on whole‐body postoperative gait biomechanics, comparing adjusted mechanical alignment (aMA) and inverse kinematic alignment (iKA).

Methods

Thirty patients undergoing primary TKA were included: 15 in the aMA group (17 knees) and 15 in the iKA group (19 knees), assessed 2 years post‐surgery. A healthy control group of 15 participants, matched for age, sex and body mass index (BMI), was included. Postoperative spatiotemporal and kinematic gait parameters were measured using 3D motion capture during gait.

Results

The aMA group demonstrated persistent knee flexion around midstance during the stance phase ( p = 0.002, >10.00°), reduced knee flexion at swing onset ( p = 0.011, −12.00°), and decreased ankle plantarflexion ( p = 0.002, −8.00°). Additionally, the aMA group showed reduced hip extension ( p < 0.001), increased anterior pelvic tilt ( p < 0.001), exaggerated thorax flexion ( p = 0.003) and altered elbow motion ( p < 0.015). In contrast, the iKA group exhibited gait patterns more closely resembling healthy controls, with a greater range of motion (ROM) at the hip, knee and ankle, improved ankle and foot progression angles, and no differences in thorax posture or elbow angles compared to controls.

Conclusions

These findings underscore the integrated nature of gait biomechanics and suggest that subtle modifications to the knee joint line may contribute to widespread kinematic adaptations. Preserving static native tibial alignment through personalised surgical strategies may, therefore, enhance functional outcomes following TKA. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GaitArthroplasty, Replacement, KneeTibiaOsteoarthritis, KneeHumansFemaleBiomechanical PhenomenaAgedMaleRange of Motion, ArticularMiddle AgedKnee JointCase-Control Studies

Stichwörter der Autor:innen

alignmentfunctional activitiesgaitjoint line obliquitytotal knee arthroplastywhole body

Autor:innen und Institutionen

  • Department of Rehabilitation Sciences, KU Leuven, Brugge, Belgium.
  • Department of Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Orthopaedic Surgery, AZ Delta, Roeselare, Belgium.

ORCID-Profile: Zhijun Li, Kurt Claeys

Zitieren

APA

Li, Z., Winnock de Grave, P., Van Criekinge, T., Luyckx, T., & Claeys, K. (2026). Static native tibial alignment in total knee arthroplasty optimises whole‐body gait kinematics. Knee Surgery, Sports Traumatology, Arthroscopy, 34(11), 4049-4062. https://doi.org/10.1002/ksa.70356

Vancouver

Li Z, Winnock de Grave P, Van Criekinge T, Luyckx T, Claeys K. Static native tibial alignment in total knee arthroplasty optimises whole‐body gait kinematics. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(11):4049-4062. doi:10.1002/ksa.70356

BibTeX
@article{Li2026,
  author = {Li, Zhijun and Winnock de Grave, Philip and Van Criekinge, Tamaya and Luyckx, Thomas and Claeys, Kurt},
  title = {Static native tibial alignment in total knee arthroplasty optimises whole‐body gait kinematics},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {11},
  pages = {4049--4062},
  doi = {10.1002/ksa.70356}
}
Kostenlos starten →