EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Unworn cartilage in total knee arthroplasty strongly deviates from 2 mm: MRI, robotic‐assisted and ruler assessment

Antonio Klasan, Victoria Anelli-Monti, Alexander Johannes Nedopil

Knee Surgery, Sports Traumatology, Arthroscopy · 2025-09 · 33 (9) · 3205-3210

DOI: 10.1002/ksa.12671 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025-04. Verfasst von Antonio Klasan und 2 weiteren Autor:innen. Beteiligte Einrichtung: AUVA UKH Steiermark, Graz, Austria. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Cartilage, Articular, Knee Joint. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Kinematic alignment (KA) in total knee arthroplasty (TKA) aims to resurface the articular surface of the pre‐arthritic knee. One cornerstone of KA TKA and the basis for conventional instrumentation (CI) is a 2 mm cartilage thickness of the healthy distal femur. This study of image‐based (CT) robotic‐assisted surgery (RAS) TKA determined (1) the difference in measuring cartilage thickness using preoperative MRI, the RAS registration probe and MRI and (2) the percentage of knees with a 2.5 mm thickness of the unworn cartilage.

Methods

Forty‐two patients undergoing a TKA using an image‐based RAS were included. Preoperative long‐leg radiographs provided the limb phenotype. The two zones of interest for cartilage thickness were the distal unworn (DU) and posterior unworn (PU) condyle. The preoperative MRI provided cartilage thickness values for both zones. Intraoperatively, the surgeon identified the zones without cartilage wear (healthy cartilage) and measured the distance between the cartilage and bone with the RAS registration probe. After resecting the condyles, a ruler was provided to measure the cartilage thickness reference.

Results

Mean patient age was 68.2 ± 4.1 years, and gender was evenly distributed. According to the phenotype classification, there were 8 NEU HKA 0°, 13 VAR HKA 3°, 9 VAR HKA 6°, 5 VAR HKA 9°, 4 VAL HKA 3°, 2 VAL HKA 6° and 1 VAL HKA 9° patient. The difference between measurement techniques was not statistically significant for both zones (DU p = 0.960, PU p = 0.267). In seven patients (16.7%), the DU cartilage thickness was >2.5 mm measured with any of the three techniques, and up to 50% of patients had unworn cartilage thickness 2.5 or

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresCartilage, ArticularKnee JointOsteoarthritis, KneeHumansMagnetic Resonance ImagingFemaleMaleAgedMiddle AgedAged, 80 and overFemur

Stichwörter der Autor:innen

MRIcartilagekinematic alignmentrobotic‐assisted surgerytotal knee arthroplastywear

Autor:innen und Institutionen

  • AUVA UKH Steiermark, Graz, Austria.
  • Johannes Kepler University Linz, Linz, Austria.
  • Adventist Health Memorial Hospital, Lodi, California, USA.
  • University of Würzburg, Würzburg, Germany.

Zitieren

APA

Klasan, A., Anelli-Monti, V., & Nedopil, A. J. (2025). Unworn cartilage in total knee arthroplasty strongly deviates from 2 mm: MRI, robotic‐assisted and ruler assessment. Knee Surgery, Sports Traumatology, Arthroscopy, 33(9), 3205-3210. https://doi.org/10.1002/ksa.12671

Vancouver

Klasan A, Anelli-Monti V, Nedopil AJ. Unworn cartilage in total knee arthroplasty strongly deviates from 2 mm: MRI, robotic‐assisted and ruler assessment. Knee Surgery, Sports Traumatology, Arthroscopy. 2025;33(9):3205-3210. doi:10.1002/ksa.12671

BibTeX
@article{Klasan2025,
  author = {Klasan, Antonio and Anelli-Monti, Victoria and Nedopil, Alexander Johannes},
  title = {Unworn cartilage in total knee arthroplasty strongly deviates from 2 mm: MRI, robotic‐assisted and ruler assessment},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  volume = {33},
  number = {9},
  pages = {3205--3210},
  doi = {10.1002/ksa.12671}
}
Kostenlos starten →