EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Reliability of Semitendinosus and Biceps Femoris Aponeurosis Thickness Using B‐Mode Ultrasound

Chrysostomos Sahinis iD, Eleftherios Kellis iD

Journal of Ultrasound in Medicine · 2025

DOI: 10.1002/jum.16616 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2025. Verfasst von Chrysostomos Sahinis und 1 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Neuromechanics, Department of Physical Education and Sport Sciences at Serres, Aristotle University of Thessaloniki, Serres, Greece. Hauptthemen laut MEDLINE: Hamstring Muscles, Aponeurosis. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of the present study was to assess the reliability of aponeurosis and muscle thickness of the hamstrings using ultrasound (US).

Methods

US images were captured from the semitendinosus (ST) and biceps femoris long head (BFlh) of 30 individuals (15 females), undergoing two testing sessions with a 24‐hour interval. Measurements were taken at six sites along the thigh at two knee angles (0° = full extension and 90°) in prone position. Aponeurosis and muscle thickness across the entire length of ST and BFlh were evaluated using computational image segmentation which generated ~360 data points per participant.

Results

The intraclass correlation coefficients ranged from 0.937 to 0.998 while the standard error of measurement varied from 0.88 to 2.72% for superficial aponeurosis, from 1.41 to 2.29% for deep aponeurosis, and from 1.50 to 4.22% for muscle thickness. The minimal detectable change ranged from 2.44 to 7.56% for the superficial aponeurosis, from 3.57 to 6.27% for deep aponeurosis, and from 4.17 to 11.70% for BF and ST muscle thickness.

Conclusions

Evaluation of hamstring aponeurosis and muscle thickness measurements at rest displayed very high reliability and, hence, such measurements can be used to diagnose changes in thickness due to injury or exercise interventions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hamstring MusclesAponeurosisHumansReproducibility of ResultsUltrasonographyFemaleMaleAdultYoung Adult

Stichwörter der Autor:innen

aponeurosisbiceps femorishamstringsmuscle thicknessreliabilityultrasound

Autor:innen und Institutionen

  • Laboratory of Neuromechanics, Department of Physical Education and Sport Sciences at Serres, Aristotle University of Thessaloniki, Serres, Greece.

ORCID-Profile: Chrysostomos Sahinis, Eleftherios Kellis

Zitieren

APA

Sahinis, C., & Kellis, E. (2025). Reliability of Semitendinosus and Biceps Femoris Aponeurosis Thickness Using B‐Mode Ultrasound. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16616

Vancouver

Sahinis C, Kellis E. Reliability of Semitendinosus and Biceps Femoris Aponeurosis Thickness Using B‐Mode Ultrasound. Journal of Ultrasound in Medicine. 2025. doi:10.1002/jum.16616

BibTeX
@article{Sahinis2025,
  author = {Sahinis, Chrysostomos and Kellis, Eleftherios},
  title = {Reliability of Semitendinosus and Biceps Femoris Aponeurosis Thickness Using B‐Mode Ultrasound},
  journal = {Journal of Ultrasound in Medicine},
  year = {2025},
  doi = {10.1002/jum.16616}
}
Kostenlos starten →