Comparison of different approaches to assess fascicle length using 3D ultrasound with cadaveric dissection as a reference for the human biceps femoris long head
Journal of Ultrasound · 2026
DOI: 10.1007/s40477-026-01203-2 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Ultrasound, 2026. Verfasst von Carmela Julia Mantecón-Tagarro und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Sport Sciences, Waseda University, Saitama, Japan. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Hamstring Muscles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS Kakenhi, JST SPRING.
Abstract (Originalsprache)
Purpose
The biceps femoris long head (BFlh) has a complex architecture, posing challenges for accurately assessing its fascicle length. This study compared four 3D ultrasound (3DUS)-based methods for estimating mid-belly BFlh fascicle length in human cadavers (n = 6 legs).
Methods
Method 1 and Method 2 assumed straight fascicles within a single longitudinal plane, aligned with the muscle axis and oriented perpendicular to either proximal or distal aponeurosis.
Method
3 represented multiplanar trajectory using two connected straight segments, whereas Method 4 further incorporated local in-plane curvature within each segment.
Results
Agreement relative to the direct measurement of fascicle length by dissection using Bland–Altman bias and 95% limits of agreement (LoA), together with mean difference. All 3DUS-based estimates showed good agreement with dissection (bias < 7.5%, LoA < 18.8 mm, mean differences < 7 mm).
Method
3 and Method 4 yielded the lowest bias, narrowest limits of agreement, and smallest mean differences. While repeated-measures ANOVA revealed a significant main effect, post hoc analysis did not identify significant differences between methods (all p ≥ 0.096). All methods demonstrated good intra-rater repeatability (ICC (3,1) = 0.77–0.87) and moderate measurement precision (SEM = 5.51–8.74%).
Conclusion
Overall, these findings suggest that a two-plane approach yields higher accuracy for BFlh fascicle length measurements than approaches assuming straight fascicles within a single plane.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Sport Sciences, Waseda University, Saitama, Japan.
- Human Performance Laboratory, Comprehensive Research Organization, Waseda University, Tokyo, Japan.
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences and, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, Van Der Boechorststraat 7, 1081 BT, Amsterdam, The Netherlands.
- Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences and, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, Van Der Boechorststraat 7, 1081 BT, Amsterdam, The Netherlands. h.maas@…
Förderung
- JSPS Kakenhi
- JST SPRING
Zitieren
APA
Mantecón-Tagarro, C. J., Weide, G., Kawakami, Y., & Maas, H. (2026). Comparison of different approaches to assess fascicle length using 3D ultrasound with cadaveric dissection as a reference for the human biceps femoris long head. Journal of Ultrasound. https://doi.org/10.1007/s40477-026-01203-2
Vancouver
Mantecón-Tagarro CJ, Weide G, Kawakami Y, Maas H. Comparison of different approaches to assess fascicle length using 3D ultrasound with cadaveric dissection as a reference for the human biceps femoris long head. Journal of Ultrasound. 2026. doi:10.1007/s40477-026-01203-2
BibTeX
@article{MantecnTagarro2026,
author = {Mantecón-Tagarro, Carmela Julia and Weide, Guido and Kawakami, Yasuo and Maas, Huub},
title = {Comparison of different approaches to assess fascicle length using 3D ultrasound with cadaveric dissection as a reference for the human biceps femoris long head},
journal = {Journal of Ultrasound},
year = {2026},
doi = {10.1007/s40477-026-01203-2}
}
EUVIMED