EUVIMEDEUVIMED entdecken
Leitlinie

AIUM Official Statement: Guidelines for Cleaning and Preparing External‐ and Internal‐Use Ultrasound Transducers and Equipment Between Patients as Well as Safe Handling and Use of Ultrasound Coupling Gel

Journal of Ultrasound in Medicine · 2023

DOI: 10.1002/jum.16167 ↗

Kurz gefasst

Leitlinie in der Zeitschrift Journal of Ultrasound in Medicine, 2023. Hauptthemen laut MEDLINE: Transducers, Equipment Contamination. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

which causes COVID-19, can be found online.5 If LLD agents are depleted, additional cleaning should include soap and water.4 However, this does not complete the disinfection.4 If indicated but no transducer covers are available, medical gloves or other physical barriers (eg, compatible medical dressings) should be used.• Education and execution: Dissemination of cleaning guidelines is essential and so is their proper execution.6 • Equipment: Cleaning involves all ancillary equipment utilized during the procedure at hand.In addition to LLD cleaning, a cover sheet may be used as a physical barrier between the keyboard/console and the operator.If possible, use a dedicated system (scanner and transducers) for COVID-19, positive or suspected, patients.COVID-19 is viable on plastic surfaces for up to 72 hours.7 • Special attention needs to be paid to COVID-19 and other respiratory infection cases requiring aerosolization procedures (eg, mechanical ventilation, aerosolization application, etc).In such cases, a transducer cover should be used, and the entire equipment requires full LLD (top to bottom) as pathogens are likely to become airborne.• Always follow manufacturer guidance and institutional guidelines.Sections 1. Procedural guidelines for transducer cleaning and preparation 2. New literature and other relevant guidelines 3. Safe handling and use of ultrasound coupling gel 4. Safe handling of ultrasound scanners and other equipment 5. Prevent misdiagnosis due to the use of damaged ultrasound transducers Section I: Procedural Guidelines for Transducer Cleaning and PreparationProcedural Graphics (Figure 1).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TransducersEquipment ContaminationHumansUltrasonographyGelsEquipment Design

Substanzen

Gels

Zitieren

APA

(2023). AIUM Official Statement: Guidelines for Cleaning and Preparing External‐ and Internal‐Use Ultrasound Transducers and Equipment Between Patients as Well as Safe Handling and Use of Ultrasound Coupling Gel. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16167

Vancouver

AIUM Official Statement: Guidelines for Cleaning and Preparing External‐ and Internal‐Use Ultrasound Transducers and Equipment Between Patients as Well as Safe Handling and Use of Ultrasound Coupling Gel. Journal of Ultrasound in Medicine. 2023. doi:10.1002/jum.16167

BibTeX
@article{euvimed2023,
  title = {AIUM Official Statement: Guidelines for Cleaning and Preparing External‐ and Internal‐Use Ultrasound Transducers and Equipment Between Patients as Well as Safe Handling and Use of Ultrasound Coupling Gel},
  journal = {Journal of Ultrasound in Medicine},
  year = {2023},
  doi = {10.1002/jum.16167}
}
Kostenlos starten →